The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Consistent image registration
Abstract
This paper presents a new method for image registration based on jointly estimating the forward and reverse transformations between two images while constraining these transforms to be inverses of one another. This approach produces a consistent set of transformations that have less pairwise registration error, i.e., better correspondence, than traditional methods that estimate the forward and reverse transformations independently. The transformations are estimated iteratively and are restricted to preserve topology by constraining them to obey the laws of continuum mechanics. The transformations are parameterized by a Fourier series to diagonalize the covariance structure imposed by the continuum mechanics constraints and to provide a computationally efficient numerical implementation. Results using a linear elastic material constraint are presented using both magnetic resonance and X-ray computed tomography image data. The results show that the joint estimation of a consistent set of forward and reverse transformations constrained by linear-elasticity give better registration results than using either constraint alone or none at all.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Cited by
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Self-citationDeformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“to tackle this shortcoming, Christensen and Johnson [19] pro-”
BackgroundInfluentialA Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Symmetric Log-Domain Diffeomorphic Registration: A Demons-Based Approach
Vercauteren, T., Pennec, X., Perchant, A., & Ayache, N. (2008) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-85988-8_90 · Cited by 342
Evaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
Metadata
- Authors
- Christensen, G. E., & Johnson, H. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001-07
- Volume
- 20
- Issue
- 7
- Pages
- 568-582
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2001666669
- Cited by
- 636
- References
- 3
- FWCI
- 28.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Consistent image registration. https://app.cochat.ai/papers/10.1109/42.932742
- The paper
- Christensen, G. E., & Johnson, H. J. (2001). Consistent image registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.932742
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.