The Scotopic Visibility Function
Open accessThe DOI matches its Crossref record.
Abstract
The scotopic (dark-adaptation) visibility of radiation through the spectrum has been determined for fifty observers under 30 years of age. A modified photometric matching method was used at a very low brightness (3 × 10 -6 candles/ft 2 or 3.2 × 10 -9 stilbs). A subsidiary investigation showed that the ultimate scotopic curve was approximated closely. Another demonstrated the effect of age, showing a progressive decrease in sensitivity at the blue end of the spectrum with increasing age, the effect first becoming noticeable at about 30 years of age. A detailed comparison of the present results with those of previous workers is made and reasons for discrepancies are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pokorny, J., Smith, V. C., & Lutze, M. (1987) · Applied Optics · doi:10.1364/ao.26.001437 · Cited by 509
Spectral sensitivities of the human cones
Stockman, A., MacLeod, D. I. A., & Johnson, N. E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.002491 · Cited by 404
Spectral transmission of the human ocular media
Norren, D. V., & Vos, J. J. (1974) · Vision Research · doi:10.1016/0042-6989(74)90222-3 · Cited by 377
(1987) · PubMed · Cited by 290
McDougal, D. H., & Gamlin, P. D. (2010) · Vision Research · doi:10.1016/j.visres.2009.10.012 · Cited by 273
Optical density of the aging human ocular media in the visible and the UV
van de Kraats, J., & van Norren, D. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001842 · Cited by 194
An Operational Near-Infrared Fluorescence Imaging System Prototype for Large Animal Surgery
De Grand, A. M., & Frangioni, J. V. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200607 · Cited by 189
Photoreceptor spectral sensitivities: Common shape in the long-wavelength region
Lamb, T. D. (1995) · Vision Research · doi:10.1016/0042-6989(95)00114-f · Cited by 179
A proposed unified system of photometry
Rea, M., Bullough, J., Freyssinier-Nova, J., & Bierman, A. (2004) · Lighting Research & Technology · doi:10.1191/1365782804li114oa · Cited by 177
The Visual Cells and Visual Pigments of the Vertebrate Eye
Crescitelli, F. (1972) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-65066-6_8 · Cited by 173
Wald, G., & Brown, P. K. (1958) · Science · doi:10.1126/science.127.3292.222 · Cited by 160
Markwell, E. L., Feigl, B., & Zele, A. J. (2010) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2010.00479.x · Cited by 158
“Cones are fewer in number(90) but cover a broader spectral range compared to rods.(22) Below cone threshold, greater initial constriction is produced by a short wavelength compared to a long wavelength stimulus of equal intensity(91) due to rod sensitivity being higher at shorter wavelengths.”
BackgroundSensitivity of mammalian cone photoreceptors to infrared light
Vinberg, F., Palczewska, G., Zhang, J., Komar, K., Wojtkowski, M., Kefalov, V. J., & Palczewski, K. (2019) · Neuroscience · doi:10.1016/j.neuroscience.2019.07.047 · Cited by 15
Metadata
- Authors
- Crawford, B. H.
- Venue
- Proceedings of the Physical Society. Section B
- Publisher
- IOP Publishing
- Published
- 1949-05-01
- Volume
- 62
- Issue
- 5
- Pages
- 321-334
- ISSN
- 0370-1301 (ISSN-L)
- OpenAlex
- W2071781441
- Cited by
- 164
- References
- 0
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.