The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Optical density of the aging human ocular media in the visible and the UV
Abstract
We analyzed the literature on the absorption in the young and aging human eye media. Five templates were derived to provide an adequate description of the spectra from 300 to 700 nm for the lens, cornea, aqueous, and vitreous. Two templates were found in all media. They stand for Rayleigh scatter and the absorbance of tryptophan. Three additional templates for the lens represent absorbance in kynurenine derivatives, such as 3-hydroxykynurenine glucoside (3HKG), and absorbance in two substances found at older age. Except for Rayleigh scatter, all templates have a Gaussian shape. Aging-trend functions were derived that show a linear slope on an age-squared scale. The result can be used to correct for media losses in visual perception tasks, in fundus reflectometry, and in studies on light damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spectral transmission of the human ocular media
Norren, D. V., & Vos, J. J. (1974) · Vision Research · doi:10.1016/0042-6989(74)90222-3 · Cited by 377
Self-citationAge-related changes in the central visual field for short-wavelength-sensitive pathways
Johnson, C. A., Adams, A. J., Twelker, J. D., & Quigg, J. M. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.002131 · Cited by 132
Light transmittance of the human cornea from 320 to 700 nm for different ages
Van Den Berg, T. J. T. P., & Tan, K. E. W. P. (1994) · Vision Research · doi:10.1016/0042-6989(94)90146-5 · Cited by 122
The post-mortem preservation of the transmissivity of the human crystalline lens
Weale, R. A. (1985) · Experimental Eye Research · doi:10.1016/0014-4835(85)90037-5 · Cited by 12
Cited by
Atchison, D. A. (2018) · Encyclopedia of Modern Optics · doi:10.1016/b978-0-12-803581-8.09773-3 · Cited by 484
Light-emitting diodes (LED) for domestic lighting: Any risks for the eye?
Behar-Cohen, F., Martinsons, C., Viénot, F., Zissis, G., Barlier-Salsi, A., Cesarini, J. P., Enouf, O., Garcia, M., Picaud, S., & Attia, D. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.04.002 · Cited by 416
The susceptibility of the retina to photochemical damage from visible light
Hunter, J. J., Morgan, J. I. W., Merigan, W. H., Sliney, D. H., Sparrow, J. R., & Williams, D. R. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.11.001 · Cited by 355
Enezi, J. A., Revell, V., Brown, T., Wynne, J., Schlangen, L., & Lucas, R. (2011) · Journal of Biological Rhythms · doi:10.1177/0748730411409719 · Cited by 278
Age-related changes in optical and biometric characteristics of emmetropic eyes
Atchison, D. A., Markwell, E. L., Kasthurirangan, S., Pope, J. M., Smith, G., & Swann, P. G. (2008) · Journal of Vision · doi:10.1167/8.4.29 · Cited by 270
Metadata
- Authors
- van de Kraats, J., & van Norren, D.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2007-06-13
- Volume
- 24
- Issue
- 7
- Pages
- 1842
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2140655667
- Cited by
- 194
- References
- 4
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical density of the aging human ocular media in the visible and the UV. https://app.cochat.ai/papers/10.1364/josaa.24.001842
- The paper
- van de Kraats, J., & van Norren, D. (2007). Optical density of the aging human ocular media in the visible and the UV. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.24.001842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.