A comparative study of the magnetic properties of bulk and nanocrystalline Co3O4
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
A comparative study of the magnetic and electron paramagnetic resonance (EPR) parameters of bulk and Co3O4 nanoparticles (NP), synthesized by a sol–gel process, is presented. Both samples possess the cubic phase with a slightly lower (by 0.34%) lattice parameter for the Co3O4 NP. The average crystallite size D = 17 nm determined by x-ray diffraction (XRD) for the Co3O4 NP is quite consistent with the electron microscopic observations. The bulk Co3O4 has particle size in the 1–2 µm range. A Neel temperature of TN = 30 K (lower than the 40 K usually quoted in the literature) is determined from the analysis of the magnetic susceptibility versus temperature data for bulk Co3O4. This TN = 30 K is in excellent agreement with the TN = 29.92 K reported from specific heat measurements. The Co3O4 NP powder exhibits a still lower TN = 26 K, possibly due to the associated finite size effects. The values of coercivity, Hc = 250 Oe, and exchange bias, He = −350 Oe, together with the training effect have been observed in the Co3O4 NP sample (cooled in 20 kOe). Both Hc and He approach zero as . For T>TN, the χ versus T data for both samples fit the modified Curie–Weiss law (χ = χ0+C/(T+θ)). The magnitudes of C, θ and TN are used to determine the following: exchange constants J1ex = 11.7 K, J2ex = 2.3 K, and magnetic moment per Co2+ ion μ = 4.27 μB for bulk Co3O4; and J1ex = 11.5 K, J2ex = 2.3 K and μ = 4.09 μB for Co3O4 NP. EPR yields a single Lorentzian line near g = 2.18 in both samples but with a linewidth ΔH that is larger for the Co3O4 NP. Details of the temperature dependence of ΔH, line intensity I0, and disappearance of the EPR on approach to TN are different for the two samples. These effects are discussed in terms of spin–phonon interaction and additional surface anisotropy present in Co3O4 NP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
X-ray line broadening from filed aluminium and wolfram
Williamson, G. K., & Hall, W. H. (1953) · Acta Metallurgica · doi:10.1016/0001-6160(53)90006-6 · Cited by 10,530
The Physical Principles of Magnetism
(1967) · Students Quarterly Journal · doi:10.1049/sqj.1967.0017 · Cited by 1,511
Exchange Narrowing in Paramagnetic Resonance
Anderson, P. W., & Weiss, P. R. (1953) · Reviews of Modern Physics · doi:10.1103/revmodphys.25.269 · Cited by 1,289
Magnetic Relaxation in Fine‐Particle Systems
Dormann, J. L., Fiorani, D., & Tronc, E. (1997) · Advances in Chemical Physics · doi:10.1002/9780470141571.ch4 · Cited by 983 · cited 1×
“atoms with the decrease in particle size D [1, 2].”
BackgroundThe Physical Principles of Magnetism
Morrish, A. H. (2001) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546581 · Cited by 677
The magnetic structure of Co3O4
Roth, W. L. (1964) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(64)90156-8 · Cited by 621
Exchange Anisotropy in Nanocasted Co3O4 Nanowires
Salabaş, E. L., Rumplecker, A., Kleitz, F., Radu, F., & Schüth, F. (2006) · Nano Letters · doi:10.1021/nl060528n · Cited by 254
Magnetic properties of nearly defect-free maghemite nanocrystals
Dutta, P., Manivannan, A., Seehra, M. S., Shah, N., & Huffman, G. P. (2004) · Physical Review B · doi:10.1103/physrevb.70.174428 · Cited by 172
Self-citationNethravathi, C., Sen, S., Ravishankar, N., Rajamathi, M., Pietzonka, C., & Harbrecht, B. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp050725v · Cited by 159
Antisymmetric Exchange and Exchange-Narrowed Electron-Paramagnetic-Resonance Linewidths
Castner, T. G., & Seehra, M. S. (1971) · Physical review. B, Solid state · doi:10.1103/physrevb.4.38 · Cited by 110
Self-citationFinite size effects on the moment and ordering temperature in antiferromagnetic CoO layers
Tang, Y., Smith, D. J., Zink, B. L., Hellman, F., & Berkowitz, A. E. (2003) · Physical review. B, Condensed matter · doi:10.1103/physrevb.67.054408 · Cited by 101
Cited by
Gerken, J. B., McAlpin, J. G., Chen, J. Y. C., Rigsby, M. L., Casey, W. H., Britt, R. D., & Stahl, S. S. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205647m · Cited by 814
Westerhaus, F. A., Jagadeesh, R. V., Wienhöfer, G., Pohl, M.-M., Radnik, J., Surkus, A.-E., Rabeah, J., Junge, K., Junge, H., Nielsen, M., et al. (2013) · Nature Chemistry · doi:10.1038/nchem.1645 · Cited by 732
Wu, T., Ren, X., Sun, Y., Sun, S., Xian, G., Scherer, G. G., Fisher, A. C., Mandler, D., Ager, J. W., Grimaud, A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23896-1 · Cited by 476
Xiao, J., Liu, P., Wang, C. X., & Yang, G. W. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.02.004 · Cited by 352
Meher, S. K., & Rao, G. R. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp209165v · Cited by 272
Metadata
- Authors
- Dutta, P., Seehra, M. S., Thota, S., & Kumar, J.
- Venue
- Journal of Physics: Condensed Matter
- Publisher
- IOP Publishing
- Published
- 2007-12-07
- Volume
- 20
- Issue
- 1
- Pages
- 015218
- ISSN
- 0953-8984 (ISSN-L)
- 1361-648X
- OpenAlex
- W2082434370
- Cited by
- 236
- References
- 11
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.