Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Broadband dielectric spectrometry of liquids and biosystems

Open access
Kaatze, Udo, Feldman, Yuri·2006·Measurement Science and Technology

Abstract

This review provides a short introduction into the basic principles of dielectric spectroscopy and it covers modern methods in use to measure the dielectric properties of liquid samples over the frequency range from about 10 −6 Hz to 10 12 Hz. The approaches described include frequency domain and time domain techniques, low frequency, high frequency and microwave measurement systems, as well as broadband and spot-frequency modes of operation. Reflection, transmission and resonant methods are presented, sketches of suitable sensors and block diagrams of measurement set-ups are shown. Accuracy aspects and the merits and limitations of the different techniques of measurement are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-0233/17/2/r01

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 174

Metadata

Authors
Kaatze, U., & Feldman, Y.
Venue
Measurement Science and Technology
Published
2005-12-23
Volume
17
Issue
2
Pages
R17-R35
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2038169401
Cited by
174
References
2
FWCI
5.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Broadband dielectric spectrometry of liquids and biosystems. https://app.cochat.ai/papers/10.1088/0957-0233/17/2/r01
The paper
Kaatze, U., & Feldman, Y. (2006). Broadband dielectric spectrometry of liquids and biosystems. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/17/2/r01

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.