Digital particle image velocimetry (DPIV) robust phase correlation
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A novel correlation technique, the robust phase correlation (RPC), is introduced which amplifies the signal-to-noise ratio of the DPIV cross-correlation to produce velocity estimations that are accurate and robust to a variety of image conditions. Specifically, this estimator shows substantial resilience against additive background noise non-uniform illumination and thermal noise effects. In addition, the RPC is able to substantially reduce bias errors and peak locking in the presence of high shear and rotational motion in comparison with standard cross-correlation algorithms. The success of this technique relies upon an analytical decomposition of the DPIV signal-to-noise ratio, which is then applied as a spectral filter in a novel implementation of the generalized cross-correlation (GCC). The RPC also utilizes advanced windowing techniques to attenuate Fourier-based errors. Because of the GCC filtering, the application of windowing in the RPC is not susceptible to the effects of additive background noise that commonly causes errors for windowed cross-correlation estimation. The RPC estimator is validated using both artificial images and experimental data to demonstrate its enhanced measurement capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433 · cited 1×
“These filtering operations have successfully demonstrated their potential for the time delay estimation for finite length noisy signals common to RADAR systems [12], which can be considered parallel to the spatial shift of finite size, noisy DPIV images.”
BackgroundDigital particle image velocimetry
Willert, C. E., & Gharib, M. (1991) · Experiments in Fluids · doi:10.1007/bf00190388 · Cited by 1,991 · cited 1×
“Over the past 20 years [2], many efforts have been directed toward the refinement of the basic digital algorithms developed by Willert and Gharib [3].”
MethodFundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425
Twenty years of particle image velocimetry
Adrian, R. J. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0991-7 · Cited by 1,267 · cited 2×
“Although a vast amount of research is dedicated to the development of advanced algorithms, improvements on the fundamental processing technique are still needed [2].”
BackgroundMethodUniversal outlier detection for PIV data
Westerweel, J., & Scarano, F. (2005) · Experiments in Fluids · doi:10.1007/s00348-005-0016-6 · Cited by 1,239 · cited 2×
“The erroneous vectors were determined using the Universal Outlier Detection [30] with a threshold of 3.”
MethodIterative image deformation methods in PIV
Scarano, F. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/1/201 · Cited by 842
Carter, G., Knapp, C., & Nuttall, A. (1973) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1973.1162496 · Cited by 514 · cited 1×
“Windowing and averaging the input power spectra is commonly used to improve the estimate of the crosscoherence [17], but works best for larger signal lengths.”
MethodA PIV Algorithm for Estimating Time-Averaged Velocity Fields
Meinhart, C. D., Wereley, S. T., & Santiago, J. G. (2000) · Journal of Fluids Engineering · doi:10.1115/1.483256 · Cited by 499
Effect of resolution on the speed and accuracy of particle image velocimetry interrogation
Prasad, A. K., Adrian, R. J., Landreth, C. C., & Offutt, P. W. (1992) · Experiments in Fluids · doi:10.1007/bf00218156 · Cited by 493
Westerweel, J., Dabiri, D., & Gharib, M. (1997) · Experiments in Fluids · doi:10.1007/s003480050082 · Cited by 476 · cited 6×
“For a DWO, these low displacement erroneous vectors are very hard to detect and often appear as high RMS error.”
MethodInfluential
Cited by
PIV uncertainty quantification by image matching
Sciacchitano, A., Wieneke, B., & Scarano, F. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/4/045302 · Cited by 286
Uncertainty quantification in particle image velocimetry
Sciacchitano, A. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/ab1db8 · Cited by 268
Tong, X., Ye, Z., Xu, Y., Gao, S., Xie, H., Du, Q., Liu, S., Xu, X., Liu, S., Luan, K., et al. (2019) · IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing · doi:10.1109/jstars.2019.2937690 · Cited by 159
Buchanan, C. F., Voigt, E. E., Szot, C. S., Freeman, J. W., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0731 · Cited by 143
Self-citation
Metadata
- Authors
- Eckstein, A., & Vlachos, P. P.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2009-04-03
- Volume
- 20
- Issue
- 5
- Pages
- 055401
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W1978407809
- Cited by
- 178
- References
- 18
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.