The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A PIV Algorithm for Estimating Time-Averaged Velocity Fields
Abstract
A PIV algorithm is presented for estimating time-averaged or phase-averaged velocity fields. The algorithm can be applied to situations where signal strength is not sufficient for standard cross correlation techniques, such as a low number of particle images in an interrogation spot, or poor image quality. The algorithm can also be used to increase the spatial resolution of measurements by allowing smaller interrogation spots than those required for standard cross correlation techniques. The quality of the velocity measurements can be dramatically increased by averaging a series of instantaneous correlation functions, before determining the location of the signal peak, as opposed to the commonly used technique of estimating instantaneous velocity fields first and then averaging the velocity fields. The algorithm is applied to a 30μm×300μm microchannel flow. [S0098-2202(00)00602-7]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Fundamentals of digital particle image velocimetry
Westerweel, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/12/002 · Cited by 1,425
Theory of cross-correlation analysis of PIV images
Keane, R. D., & Adrian, R. J. (1992) · Flow Turbulence and Combustion · doi:10.1007/bf00384623 · Cited by 1,227
A particle image velocimetry system for microfluidics
Santiago, J. G., Wereley, S. T., Meinhart, C. D., Beebe, D. J., & Adrian, R. J. (1998) · Experiments in Fluids · doi:10.1007/s003480050235 · Cited by 1,174
Self-citationOptimization of particle image velocimeters. I. Double pulsed systems
Keane, R. D., & Adrian, R. J. (1990) · Measurement Science and Technology · doi:10.1088/0957-0233/1/11/013 · Cited by 816
PIV measurements of a microchannel flow
Meinhart, C. D., Wereley, S. T., & Santiago, J. G. (1999) · Experiments in Fluids · doi:10.1007/s003480050366 · Cited by 802
Self-citationEfficient detection of spurious vectors in particle image velocimetry data
Westerweel, J. (1994) · Experiments in Fluids · doi:10.1007/bf00206543 · Cited by 486
Cited by
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
Metadata
- Authors
- Meinhart, C. D., Wereley, S. T., & Santiago, J. G.
- Venue
- Journal of Fluids Engineering
- Publisher
- ASME International
- Published
- 2000-02-02
- Volume
- 122
- Issue
- 2
- Pages
- 285-289
- ISSN
- 0098-2202 (ISSN-L)
- 1528-901X
- OpenAlex
- W2138670890
- Cited by
- 499
- References
- 7
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A PIV Algorithm for Estimating Time-Averaged Velocity Fields. https://app.cochat.ai/papers/10.1115/1.483256
- The paper
- Meinhart, C. D., Wereley, S. T., & Santiago, J. G. (2000). A PIV Algorithm for Estimating Time-Averaged Velocity Fields. Journal of Fluids Engineering. https://doi.org/10.1115/1.483256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.