Disposable blood potassium sensors based on screen-printed thick film electrodes

Xu, Hui, Yang, Xiaoxi, Wang, You, Zheng, Junbao, Luo, Zhiyuan, Li, Guang·2010·Measurement Science and Technology

Abstract

A sensor based on the screen-printing technique for the rapid blood potassium test was developed. The sensor consists of a thick film potassium ion-selective electrode and a reference electrode. Poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrenesulfonate) (PSS) was screen-printed on carbon electrodes as an internal solid contact layer for both ion-selective and reference electrodes. PVC membranes with and without selective ionphore valinomycin were coated on the PEDOT/PSS layer to form potassium ion-selective and reference electrodes, respectively. The potentiometric response characters were evaluated. The response time of the sensor was 15 s when less than 15 µL of sample was applied. The sensitivity of the potassium sensor was around 60 mV per decade, while the potentiometric log selectivity coefficients were −3.43 and −3.48 for Na + and Ca 2+ , respectively.

Integrity signals

Registry

Crossref · 10.1088/0957-0233/21/5/055802

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The K+ sensor demonstrated a smaller and faster response compared to current standard of care (e.g., clinical laboratory electrolyte analyzer) and required a smaller blood sample volume.

    “The sensor demonstrated a smaller and faster response compared to current standard of care (e.g., clinical laboratory electrolyte analyzer) and required a smaller blood sample volume.”
  • Xu et al. devised a low-cost method to mass produce disposable portable sensors for point of care testing of K+ from blood serum.

    “Xu et al.43 devised a low-cost method to mass produce disposable portable sensors for point of care testing of K+ from blood serum.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Xu, H., Yang, X., Wang, Y., Zheng, J., Luo, Z., & Li, G.
Affiliations
  • State Key Laboratory of Industrial Control Technology (CN)
  • Zhejiang University (CN)
  • Zhejiang Sci-Tech University (CN)
  • Royal Holloway University of London (GB)
Venue
Measurement Science and Technology
Published
2010-04-13
Volume
21
Issue
5
Pages
055802
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2059222337
Cited by
14
References
24
Citations by year
2021: 1 · 2020: 2 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 1 · 2013: 1 · 2012: 2
FWCI
0.71
Type
journal article
Language
en
Open access
closed
Locations
Measurement Science and Technology (publishedVersion)
Topics
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
disposable sensors, screen-printed electrodes, thick-film electrodes, ion-selective electrodes, reference electrode, PEDOT:PSS, valinomycin, PVC membrane, potentiometric sensors, carbon electrodes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review