The use of the PeakForceTMquantitative nanomechanical mapping AFM-based method for high-resolution Young's modulus measurement of polymers
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PeakForce TM quantitative nanomechanical mapping (QNM TM ) is a new atomic force microscopy technique for measuring Young's modulus of materials with high spatial resolution and surface sensitivity by probing at the nanoscale. In this work, modulus results from PeakForce™ QNM™ using three different probes are presented for a number of different polymers with a range of Young's moduli that were measured independently by instrumented (nano) indentation testing (IIT). The results from the diamond and silicon AFM probes were consistent and in reasonable agreement with IIT values for the majority of samples. It is concluded that the technique is complementary to IIT; calibration requirements and potential improvements to the technique are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Effect of contact deformations on the adhesion of particles
Derjaguin, B. V., Muller, V. M., & Toporov, Y. P. (1975) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(75)90018-1 · Cited by 4,589
Phase imaging and stiffness in tapping-mode atomic force microscopy
Magonov, S. N., Elings, V., & Whangbo, M.-H. (1997) · Surface Science · doi:10.1016/s0039-6028(96)01591-9 · Cited by 1,020
Burnham, N. A., & Colton, R. J. (1989) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576168 · Cited by 713
Atomic Resolution with Atomic Force Microscope
Binnig, G., Gerber, C., Stoll, E., Albrecht, T. R., & Quate, C. F. (1987) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/3/12/006 · Cited by 559
Using force modulation to image surface elasticities with the atomic force microscope
Maivald, P., Butt, H. J., Gould, S. A. C., Prater, C. B., Drake, B., Gurley, J. A., Elings, V. B., & Hansma, P. K. (1991) · Nanotechnology · doi:10.1088/0957-4484/2/2/004 · Cited by 525
An atomic force microscope tip designed to measure time-varying nanomechanical forces
Sahin, O., Magonov, S., Su, C., Quate, C. F., & Solgaard, O. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.226 · Cited by 481
Clifford, C. A., & Seah, M. P. (2005) · Applied Surface Science · doi:10.1016/j.apsusc.2005.08.090 · Cited by 163
Lin, D. C., Dimitriadis, E. K., & Horkay, F. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2800826 · Cited by 162
Richter, F., Herrmann, M., Molnar, F., Chudoba, T., Schwarzer, N., Keunecke, M., Bewilogua, K., Zhang, X. W., Boyen, H. ‐., & Ziemann, P. (2006) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2006.08.124 · Cited by 48
Cited by
Garcia, R. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00318b · Cited by 480
Li, Y., Yang, J., Pan, Z., & Tong, W. (2020) · Fuel · doi:10.1016/j.fuel.2019.116352 · Cited by 372
Fracture resistance measurement of fused deposition modeling 3D printed polymers
Aliheidari, N., Tripuraneni, R., Ameli, A., & Nadimpalli, S. (2017) · Polymer Testing · doi:10.1016/j.polymertesting.2017.03.016 · Cited by 244
Fast nanomechanical spectroscopy of soft matter
Herruzo, E. T., Perrino, A. P., & Garcia, R. (2014) · Nature Communications · doi:10.1038/ncomms4126 · Cited by 231
Aliheidari, N., Christ, J., Tripuraneni, R., Nadimpalli, S., & Ameli, A. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.07.001 · Cited by 230
Metadata
- Authors
- Young, T. J., Monclus, M. A., Burnett, T. L., Broughton, W. R., Ogin, S. L., & Smith, P. A.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2011-10-24
- Volume
- 22
- Issue
- 12
- Pages
- 125703
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2070437656
- Cited by
- 338
- References
- 10
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.