The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The measurement of dissolved and gaseous carbon dioxide concentration
Abstract
In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO 2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO 2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO 2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO 2. In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Catheter-type sensor for potentiometric monitoring of oxygen, pH and carbon dioxide
Meruva, R. K., & Meyerhoff, M. E. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00097-3 · Cited by 64
Cited by
Local reaction environment in electrocatalysis
Chen, C., Jin, H., Wang, P., Sun, X., Jaroniec, M., Zheng, Y., & Qiao, S.-Z. (2024) · Chemical Society Reviews · doi:10.1039/d3cs00669g · Cited by 381
Interfacial Electrolyte Effects on Electrocatalytic CO2 Reduction
Deng, B., Huang, M., Zhao, X., Mou, S., & Dong, F. (2022) · ACS Catalysis · doi:10.1021/acscatal.1c03501 · Cited by 326
ZHAN, N., HUANG, Y., RAO, Z., & ZHAO, X.-L. (2016) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(16)60913-1 · Cited by 34
Metadata
- Authors
- Zosel, J., Oelßner, W., Decker, M., Gerlach, G., & Guth, U.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2011-05-20
- Volume
- 22
- Issue
- 7
- Pages
- 072001
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2069264006
- Cited by
- 159
- References
- 2
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The measurement of dissolved and gaseous carbon dioxide concentration. https://app.cochat.ai/papers/10.1088/0957-0233/22/7/072001
- The paper
- Zosel, J., Oelßner, W., Decker, M., Gerlach, G., & Guth, U. (2011). The measurement of dissolved and gaseous carbon dioxide concentration. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/22/7/072001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.