The measurement of dissolved and gaseous carbon dioxide concentration
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO 2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO 2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO 2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO 2. In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
The HITRAN 2008 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Barbe, A., Benner, D. C., Bernath, P. F., Birk, M., Boudon, V., Brown, L. R., Campargue, A., Champion, J.-P., et al. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.02.013 · Cited by 3,335
Dickson, A. G., & Goyet, C. (1994) · doi:10.2172/10107773 · Cited by 1,167
Carbon Dioxide Supersaturation in the Surface Waters of Lakes
Cole, J. J., Caraco, N. F., Kling, G. W., & Kratz, T. K. (1994) · Science · doi:10.1126/science.265.5178.1568 · Cited by 1,135
Electrodes for Blood pO2 and pCO2 Determination
Severinghaus, J. W., & Bradley, A. F. (1958) · Journal of Applied Physiology · doi:10.1152/jappl.1958.13.3.515 · Cited by 929
Two chemosensory receptors together mediate carbon dioxide detection in Drosophila
Jones, W. D., Cayirlioglu, P., Grunwald Kadow, I., & Vosshall, L. B. (2007) · Nature · doi:10.1038/nature05466 · Cited by 708
Fundamentals of molecular spectroscopy
Banwell, C. N. (1966) · CERN Document Server (European Organization for Nuclear Research) · Cited by 520
The molecular basis of CO 2 reception in Drosophila
Kwon, J. Y., Dahanukar, A., Weiss, L. A., & Carlson, J. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700079104 · Cited by 500
The role of carbon dioxide in host-finding by mosquitoes (Diptera: Culicidae): a review
Gillies, M. T. (1980) · Bulletin of Entomological Research · doi:10.1017/s0007485300007811 · Cited by 483
Carbon Dioxide Diffusion inside Leaves
Evans, J. R., & von Caemmerer, S. (1996) · Plant Physiology · doi:10.1104/pp.110.2.339 · Cited by 408
Diffusion of CO2and other gases inside leaves
PARKHURST, D. F. (1994) · New Phytologist · doi:10.1111/j.1469-8137.1994.tb04244.x · Cited by 352
Insects breathe discontinuously to avoid oxygen toxicity
Hetz, S. K., & Bradley, T. J. (2005) · Nature · doi:10.1038/nature03106 · Cited by 343
APTE, M. G., FISK, W. J., & DAISEY, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Fiber-optic fluorosensor for oxygen and carbon dioxide
Wolfbeis, O. S., Weis, L., Leiner, M. J. P., & Ziegler, W. (1988) · Analytical Chemistry · doi:10.1021/ac00170a009 · Cited by 294
Bowling, D. R., Sargent, S. D., Tanner, B. D., & Ehleringer, J. R. (2003) · Agricultural and Forest Meteorology · doi:10.1016/s0168-1923(03)00074-1 · Cited by 272
Tectonic relations of carbon dioxide discharges and earthquakes
Irwin, W. P., & Barnes, I. (1980) · Journal of Geophysical Research: Solid Earth · doi:10.1029/jb085ib06p03115 · Cited by 263
Equilibrium studies on colorimetric plastic film sensors for carbon dioxide
Mills, A., Chang, Q., & McMurray, N. (1992) · Analytical Chemistry · doi:10.1021/ac00037a015 · Cited by 219
Review of micromachined thermopiles for infrared detection
Graf, A., Arndt, M., Sauer, M., & Gerlach, G. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/7/r01 · Cited by 218
Self-citationInstrumentation and sensors for the food industry
Kress-Rogers, E., & Christopher, J. B. B. (2001) · Woodhead Publishing Limited eBooks · doi:10.1533/9781855736481 · Cited by 210
Johnson, M. S., Billett, M. F., Dinsmore, K. J., Wallin, M., Dyson, K. E., & Jassal, R. S. (2010) · Ecohydrology · doi:10.1002/eco.95 · Cited by 205
Schulz, K. G., Riebesell, U., Rost, B., Thoms, S., & Zeebe, R. E. (2006) · Marine Chemistry · doi:10.1016/j.marchem.2005.11.001 · Cited by 193
Evolution of the Gene Lineage Encoding the Carbon Dioxide Receptor in Insects
Robertson, H. M., & Kent, L. B. (2009) · Journal of Insect Science · doi:10.1673/031.009.1901 · Cited by 186
Atmospheric carbon dioxide regulation in honey-bee (Apis mellifera) colonies
Seeley, T. D. (1974) · Journal of Insect Physiology · doi:10.1016/0022-1910(74)90052-3 · Cited by 165
Vale, G. A., & Hall, D. R. (1985) · Bulletin of Entomological Research · doi:10.1017/s0007485300014292 · Cited by 163
Potentiometric gas sensing electrodes
Ross, J. W., Riseman, J. H., & Krueger, J. A. (1973) · Pure and Applied Chemistry · doi:10.1351/pac197336040473 · Cited by 162
Eberhard, P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278642.16117.f8 · Cited by 161
Solid-state electrochemical gas sensors
Weppner, W. (1987) · Sensors and Actuators · doi:10.1016/0250-6874(87)85010-2 · Cited by 160
Erdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147
Fergus, J. W. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.07.005 · Cited by 147
A fast‐responding CO 2 microelectrode for profiling sediments, microbial mats, and biofilms
de Beer, D., Glud, A., Epping, E. H. G., & Kühl, M. (1997) · Limnology and Oceanography · doi:10.4319/lo.1997.42.7.1590 · Cited by 107
HEINICKE, J., Koch, U., & Martinelli, G. (1995) · Geophysical Research Letters · doi:10.1029/94gl03074 · Cited by 106
A High-Precision NDIR $\hbox{CO}_{2}$ Gas Sensor for Automotive Applications
Frodl, R., & Tille, T. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2006.884440 · Cited by 97
Pattison, R. N., Swamy, J. A., Mendenhall, B., Hwang, C., & Frohlich, B. T. (2000) · Biotechnology Progress · doi:10.1021/bp000089c · Cited by 90
Stange, G., Monro, J., Stowe, S., & Osmond, C. B. (1995) · Oecologia · doi:10.1007/bf00329801 · Cited by 88
Kleineidam, C. J., & Tautz, J. (1996) · Die Naturwissenschaften · doi:10.1007/bf01141981 · Cited by 86
Fiber-optic sensors for pH and carbon dioxide using a self-referencing dye
Parker, J. W., Laksin, O., Yu, C., Lau, M. L., Klima, S., Fisher, R., Scott, I. L., & Atwater, B. W. (1993) · Analytical Chemistry · doi:10.1021/ac00065a027 · Cited by 80
In vivo blood-gas and electrolyte sensors: Progress and challenges
Meyerhoff, M. E. (1993) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(93)87065-6 · Cited by 79
Response time characteristics of the pCO2 electrode
Jensen, M. A., & RECHNITZ, G. A. (1979) · Analytical Chemistry · doi:10.1021/ac50048a019 · Cited by 72
Development of a compact quantum cascade laser spectrometer for field measurements of CO2 isotopes
Weidmann, D., Wysocki, G., Oppenheimer, C., & Tittel, F. K. (2004) · Applied Physics B · doi:10.1007/s00340-004-1639-7 · Cited by 68
The reduction of CO2 on polyaniline electrode in a membrane cell
Köleli, F., Röpke, T., & Hamann, C. H. (2003) · Synthetic Metals · doi:10.1016/s0379-6779(03)00021-3 · Cited by 67
Integrated blood-gas sensor for pO2, pCO2 and pH
Arquint, P., van den Berg, A., van der Schoot, B. H., de Rooij, N. F., Bühler, H. E., Morf, W. E., & Dürselen, L. F. J. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)85396-r · Cited by 66
Frahm, B., Blank, H.-C., Cornand, P., Oelßner, W., Guth, U., Lane, P., Munack, A., Johannsen, K., & Pörtner, R. (2002) · Journal of Biotechnology · doi:10.1016/s0168-1656(02)00180-3 · Cited by 65
Self-citationCatheter-type sensor for potentiometric monitoring of oxygen, pH and carbon dioxide
Meruva, R. K., & Meyerhoff, M. E. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00097-3 · Cited by 64
Miniaturised carbon dioxide sensor designed for measurements within plant leaves
Hanstein, S. M., de Beer, D., & FELLE, H. H. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00939-x · Cited by 64
Telting‐Diaz, M., Collison, M. E., & Meyerhoff, M. E. (1994) · Analytical Chemistry · doi:10.1021/ac00076a025 · Cited by 44
Sensory and Behavioural Responses of Terrestrial Invertebrates to Biogenic Carbon Dioxide Gradients
Stange, G. (1996) · Advances in bioclimatology · doi:10.1007/978-3-642-61132-2_5 · Cited by 42
An improved Severinghaus-type carbon dioxide microelectrode for use in biofilms
Beyenal, H., Davis, C., & Lewandowski, Z. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.08.015 · Cited by 41
Flight-motor-driven respiratory air flow in the hawkmothManduca sexta
Wasserthal, L. T. (2001) · Journal of Experimental Biology · doi:10.1242/jeb.204.13.2209 · Cited by 40
Wu, L., Lange, H. C., van Gulik, W. M., & Heijnen, J. J. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10480 · Cited by 39
Early warning of disturbances in a laboratory-scale MSW biogas process
Hannsson, M., Nordberg, Å., Sundh, I., & Mathisen, B. (2002) · Water Science & Technology · doi:10.2166/wst.2002.0346 · Cited by 37
Carbon Dioxide, Dissolved (Ocean)
Zeebe, R. E., & Wolf-Gladrow, D. A. (2009) · Encyclopedia of earth sciences series/Encyclopedia of earth sciences · doi:10.1007/978-1-4020-4411-3_30 · Cited by 34
Belitz, H., Grosch, W., & Schieberle, P. (2004) · Springer eBooks · doi:10.1007/978-3-662-07279-0_11 · Cited by 31
The influence of CO2 on ISFETs with polymer membranes and characterization of a carbonate ion sensor
Abramova, N., Levichev, S., & Bratov, A. V. (2010) · Talanta · doi:10.1016/j.talanta.2010.03.034 · Cited by 18
Carolan, P. L., Wheeler, W. B., Ross, J. D., & Kemp, R. A. J. S. (2000) · PEDIATRICS · doi:10.1542/peds.105.4.774 · Cited by 16
Domingo, C., Blanch, L. L., Murias, G. E., & Luján, M. (2010) · Sensors · doi:10.3390/s100504655 · Cited by 15
Microfabricated needle-type sensors for pO/sub 2/, pCO/sub 2/, and pH
Wang, X., Suzuki, H. R., Hayashi, K., Kaneko, T., & Sunagawa, K. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2005.853594 · Cited by 14
Fetal carbon dioxide tension during human labour
Nickelsen, C., Thomsen, S. G., & Weber, T. (1986) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(86)90067-5 · Cited by 8
Cited by
Local reaction environment in electrocatalysis
Chen, C., Jin, H., Wang, P., Sun, X., Jaroniec, M., Zheng, Y., & Qiao, S.-Z. (2024) · Chemical Society Reviews · doi:10.1039/d3cs00669g · Cited by 381
Interfacial Electrolyte Effects on Electrocatalytic CO2 Reduction
Deng, B., Huang, M., Zhao, X., Mou, S., & Dong, F. (2022) · ACS Catalysis · doi:10.1021/acscatal.1c03501 · Cited by 326
Hodgkinson, J., Smith, R., Ho, W. O., Saffell, J. R., & Tatam, R. P. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.06.006 · Cited by 218
“Non-dispersive infrared (NDIR) gas sensing is one of the most widely used optical gas detection techniques, and there is a wide range of cell designs in commercial manufacture [1].”
BackgroundInfluentialReaction Environment Regulation for Electrocatalytic CO2 Reduction in Acids
Zeng, M., Fang, W., Cen, Y., Zhang, X., Hu, Y., & Xia, B. Y. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202404574 · Cited by 213
The self-powered CO2 gas sensor based on gas discharge induced by triboelectric nanogenerator
Zhao, K., Gu, G., Zhang, Y., Zhang, B., Yang, F., Zhao, L., Zheng, M., Cheng, G., & Du, Z. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.09.057 · Cited by 179
Metadata
- Authors
- Zosel, J., Oelßner, W., Decker, M., Gerlach, G., & Guth, U.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2011-05-20
- Volume
- 22
- Issue
- 7
- Pages
- 072001
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2069264006
- Cited by
- 159
- References
- 58
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.