Cited by 31Scientific Measurement and Uncertainty EvaluationAdvanced Measurement and Metrology TechniquesFlow Measurement and Analysis

Novel gravimetric measurement technique for quantitative volume calibration in the sub-microliter range

Open access
Liang, Dong, Steinert, Chris, Bammesberger, Stefan, Tanguy, Laurent, Ernst, Andreas, Zengerle, Roland, Koltay, Peter·2013·Measurement Science and Technology

Abstract

We present a novel measurement method based on the gravimetric principles adapted from the ASTM E542 and ISO 4787 standards for quantitative volume determination in the sub-microliter range.Such a method is particularly important for the calibration of non-contact micro dispensers as well as other microfluidic devices.The novel method is based on the linear regression analysis of continuously monitored gravimetric results and therefore is referred to as 'gravimetric regression method (GRM)'.In this context, the regression analysis is necessary to compensate the mass loss due to evaporation that is significant for very small dispensing volumes.A full assessment of the measurement uncertainty of GRM is presented and results in a standard measurement uncertainty around 6 nl for dosage volumes in the range from 40 nl to 1 μl.The GRM has been experimentally benchmarked with a dual-dye ratiometric photometric method (Artel Inc., Westbrook, ME, USA), which can provide traceability of measurement to the International System of Units (SI) through reference standards maintained by NIST.Good precision (max.CV = 2.8%) and consistency (bias around 7 nl in the volume range from 40 to 400 nl) have been observed comparing the two methods.Based on the ASTM and ISO standards on the one hand and the benchmark with the photometric method on the other hand, two different approaches for establishing traceability for the GRM are discussed.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-0233/24/2/025301

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liang, D., Steinert, C., Bammesberger, S., Tanguy, L., Ernst, A., Zengerle, R., & Koltay, P.
Affiliations
  • BioFluidix (Germany) (DE)
  • University of Freiburg (DE)
Corresponding author
Liang, Dong
Venue
Measurement Science and Technology
Published
2012-12-13
Volume
24
Issue
2
Pages
025301
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2008686724
Cited by
31
References
16
Citations by year
2025: 1 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 1 · 2020: 3 · 2019: 1 · 2018: 1 · 2017: 4 · 2016: 2 · 2015: 2 · 2014: 2 · 2013: 3 · 2012: 2
FWCI
3.29
Type
journal article
Language
en
Open access
Locations
Measurement Science and Technology (publishedVersion)
Funders
Bundesministerium für Bildung und Forschung
Topics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
  • Physical Sciences › Engineering › Mechanics of Materials › Flow Measurement and Analysis
Keywords
measurement uncertainty, measurement traceability, microfluidics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review