The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A method for determining the spring constant of cantilevers for atomic force microscopy
Open accessAbstract
Cantilevers fabricated by means of micromachining techniques are usually used for atomic force microscopy. In this paper, the spring constant of an atomic force microscope (AFM) cantilever is determined by using a large-scale cantilever. Since the spring constant of the large-scale cantilever is calibrated accurately, the spring constant of the AFM cantilever is determined precisely by measuring the deflections of both cantilevers simultaneously using heterodyne interferometry. The slope of the force curve gives the spring constant of the AFM cantilever. It is not necessary to measure the dimensions of the AFM cantilever in the proposed method. Although this method is simple, the spring constant of the AFM cantilever is obtained accurately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Force feedback surface force apparatus: Principles of operation
Stewart, A., & Parker, J. L. (1992) · Review of Scientific Instruments · doi:10.1063/1.1143392 · Cited by 39
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Mechanical Properties of Collagen Fibrils
Wenger, M. P. E., Bozec, L., Horton, M. A., & Mesquida, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.103192 · Cited by 566
Stolz, M., Raiteri, R., Daniels, A. U., VanLandingham, M. R., Baschong, W., & Aebi, U. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74375-1 · Cited by 454
Metadata
- Authors
- Torii, A., Sasaki, M., Hane, K., & Okuma, S.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1996-02-01
- Volume
- 7
- Issue
- 2
- Pages
- 179-184
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2028653557
- Cited by
- 282
- References
- 3
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method for determining the spring constant of cantilevers for atomic force microscopy. https://app.cochat.ai/papers/10.1088/0957-0233/7/2/010
- The paper
- Torii, A., Sasaki, M., Hane, K., & Okuma, S. (1996). A method for determining the spring constant of cantilevers for atomic force microscopy. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/7/2/010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.