Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 282

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A method for determining the spring constant of cantilevers for atomic force microscopy

Open access
Torii, Akihiro, Sasaki, Minoru, Hane, Kazuhiro, Okuma, Shigeru · 1996 · Measurement Science and Technology

Abstract

Cantilevers fabricated by means of micromachining techniques are usually used for atomic force microscopy. In this paper, the spring constant of an atomic force microscope (AFM) cantilever is determined by using a large-scale cantilever. Since the spring constant of the large-scale cantilever is calibrated accurately, the spring constant of the AFM cantilever is determined precisely by measuring the deflections of both cantilevers simultaneously using heterodyne interferometry. The slope of the force curve gives the spring constant of the AFM cantilever. It is not necessary to measure the dimensions of the AFM cantilever in the proposed method. Although this method is simple, the spring constant of the AFM cantilever is obtained accurately.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-0233/7/2/010

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 282

Metadata

Authors
Torii, A., Sasaki, M., Hane, K., & Okuma, S.
Venue
Measurement Science and Technology
Published
1996-02-01
Volume
7
Issue
2
Pages
179-184
ISSN
  • 0957-0233 (ISSN-L)
  • 1361-6501
OpenAlex
W2028653557
Cited by
282
References
3
FWCI
0.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A method for determining the spring constant of cantilevers for atomic force microscopy. https://app.cochat.ai/papers/10.1088/0957-0233/7/2/010
The paper
Torii, A., Sasaki, M., Hane, K., & Okuma, S. (1996). A method for determining the spring constant of cantilevers for atomic force microscopy. Measurement Science and Technology. https://doi.org/10.1088/0957-0233/7/2/010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.