Ultrasensitive label-free DNA analysis using an electronic chip based on carbon nanotube nanoelectrode arrays
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We report the detection of DNA PCR amplicons using an ultrasensitive label-free electronic technique based on multiwalled carbon nanotube (MWNT) nanoelectrode arrays embedded in an SiO(2) matrix. Specific PCR amplicons are reliably detected using electrochemical (EC) methods through allele-specific oligonucleotide hybridization. The inherent guanine bases in the DNA amplicon target of [Formula: see text] bases serve as signal moieties with the aid of Ru(bpy)(3)(2+) mediators, providing an amplified anodic current associated with the oxidation of guanine groups at the nanoelectrode surface. The reduced size and density of the nanoelectrode array provided by MWNTs dramatically improves the sensitivity of EC detection. In addition, the abundant guanine bases in target DNA produce a large signal. Less than [Formula: see text] target amplicons can be detected on a microspot, approaching the sensitivity limit of conventional laser-based fluorescence techniques. This method also eliminates the labelling requirement and makes the measurements much simpler. This platform can be employed for developing highly automated electronic chips with multiplex nanoelectrode arrays for quick DNA analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Strong Candidate for the Breast and Ovarian Cancer Susceptibility Gene BRCA1
Miki, Y., Swensen, J., Shattuck-Eidens, D., Futreal, P. A., Harshman, K., Tavtigian, S., Liu, Q., Cochran, C., Bennett, L. M., Ding, W., et al. (1994) · Science · doi:10.1126/science.7545954 · Cited by 6,071
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Expression profiling using cDNA microarrays
Duggan, D. J., Bittner, M., Chen, Y., Meltzer, P., & Trent, J. M. (1999) · Nature Genetics · doi:10.1038/4434 · Cited by 1,657
Fabrication and Evaluation of Nanoelectrode Ensembles
Menon, V. P., & Martin, C. R. (1995) · Analytical Chemistry · doi:10.1021/ac00109a003 · Cited by 698
Mutation detection by electrocatalysis at DNA-modified electrodes
Boon, E. M., Ceres, D. M., Drummond, T. G., Hill, M. G., & Barton, J. K. (2000) · Nature Biotechnology · doi:10.1038/80301 · Cited by 639
Carbon Nanotube Nanoelectrode Array for Ultrasensitive DNA Detection
Li, J., Ng, H. T., Cassell, A., Fan, W., Chen, H., Ye, Q., Koehne, J., Han, J., & Meyyappan, M. (2003) · Nano Letters · doi:10.1021/nl0340677 · Cited by 627
Self-citationWightman, R. M. (1981) · Analytical Chemistry · doi:10.1021/ac00232a004 · Cited by 544
Persistence Length of Single-Stranded DNA
Tinland, B., Pluen, A., Sturm, J., & Weill, G. (1997) · Macromolecules · doi:10.1021/ma970381+ · Cited by 519
Sosnowski, R. G., Tu, E., Butler, W. F., O’Connell, J. P., & Heller, M. J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.4.1119 · Cited by 453
Electrochemical Detection of Single Molecules
Fan, F.-R. F., & Bard, A. J. (1995) · Science · doi:10.1126/science.267.5199.871 · Cited by 376
Cited by
Tasis, D., Tagmatarchis, N., Bianco, A., & Prato, M. (2006) · Chemical Reviews · doi:10.1021/cr050569o · Cited by 4,273
Carbon‐Nanotube Based Electrochemical Biosensors: A Review
Wang, J. (2005) · Electroanalysis · doi:10.1002/elan.200403113 · Cited by 2,387
Environmental Applications of Carbon-Based Nanomaterials
Mauter, M. S., & Elimelech, M. (2008) · Environmental Science & Technology · doi:10.1021/es8006904 · Cited by 1,576
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
Biomolecule‐Functionalized Carbon Nanotubes: Applications in Nanobioelectronics
Katz, E., & Willner, I. (2004) · ChemPhysChem · doi:10.1002/cphc.200400193 · Cited by 749
Melechko, A. V., Merkulov, V. I., McKnight, T. E., Guillorn, M. A., Klein, K. L., Lowndes, D. H., & Simpson, M. L. (2005) · Journal of Applied Physics · doi:10.1063/1.1857591 · Cited by 664
TELES, F., & FONSECA, L. (2008) · Talanta · doi:10.1016/j.talanta.2008.07.024 · Cited by 405
Liu, J., Chou, A., Rahmat, W., Paddon‐Row, M. N., & Gooding, J. J. (2005) · Electroanalysis · doi:10.1002/elan.200403116 · Cited by 307
Qureshi, A., Kang, W. P., Davidson, J. L., & Gurbuz, Y. (2009) · Diamond and Related Materials · doi:10.1016/j.diamond.2009.09.008 · Cited by 261
A review of plasma enhanced chemical vapour deposition of carbon nanotubes
Meyyappan, M. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/21/213001 · Cited by 239
Self-citationMicroelectrode Arrays for Electrochemistry: Approaches to Fabrication
Huang, X., O'Mahony, A. M., & Compton, R. G. (2009) · Small · doi:10.1002/smll.200801593 · Cited by 232
Very High Density Sensing Arrays
LaFratta, C. N., & Walt, D. R. (2008) · Chemical Reviews · doi:10.1021/cr0681142 · Cited by 205
Electrochemical Biosensors for Medical and Food Applications
Ahmed, M. U., Hossain, M. M., & Tamiya, E. (2008) · Electroanalysis · doi:10.1002/elan.200704121 · Cited by 195
Koehne, J. E., Chen, H., Cassell, A. M., Ye, Q., Han, J., Meyyappan, M., & Li, J. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.036285 · Cited by 166
Self-citationElectrochemical biosensors at the nanoscale
Wei, D., Bailey, M. J. A., Andrew, P., & Ryhänen, T. (2009) · Lab on a Chip · doi:10.1039/b903118a · Cited by 158
Metadata
- Authors
- Koehne, J., Chen, H., Li, J., Cassell, A. M., Ye, Q., Ng, H. T., Han, J., & Meyyappan, M.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2003-10-17
- Volume
- 14
- Issue
- 12
- Pages
- 1239-1245
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W1965416558
- Cited by
- 181
- References
- 14
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.