Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record.

Polyethylene glycol-covered ultra-small Gd2O3nanoparticles for positive contrast at 1.5 T magnetic resonance clinical scanning

Open access
Fortin, Marc-André, Petoral Jr, Rodrigo M, Söderlind, Fredrik, Klasson, A, Engström, Maria, Veres, Teodor, Käll, Per-Olof, Uvdal, Kajsa · 2007 · Nanotechnology

Abstract

The size distribution and magnetic properties of ultra-small gadolinium oxide crystals (US-Gd 2 O 3 ) were studied, and the impact of polyethylene glycol capping on the relaxivity constants ( r 1 , r 2 ) and signal intensity with this contrast agent was investigated. Size distribution and magnetic properties of US-Gd 2 O 3 nanocrystals were measured with a TEM and PPMS magnetometer. For relaxation studies, diethylene glycol (DEG)-capped US-Gd 2 O 3 nanocrystals were reacted with PEG-silane (MW 5000). Suspensions were adequately dialyzed in water to eliminate traces of Gd 3+ and surfactants. The particle hydrodynamic radius was measured with dynamic light scattering (DLS) and the proton relaxation times were measured with a 1.5 T MRI scanner. Parallel studies were performed with DEG–Gd 2 O 3 and PEG-silane–SPGO (Gd 2 O 3 ,< 40 nm diameter). The small and narrow size distribution of US-Gd 2 O 3 was confirmed with TEM (∼3 nm) and DLS. PEG-silane–US-Gd 2 O 3 relaxation parameters were twice as high as for Gd–DTPA and the r 2 / r 1 ratio was 1.4. PEG-silane–SPGO gave low r 1 relaxivities and high r 2 / r 1 ratios, less compatible with positive contrast agent requirements. Higher r 1 were obtained with PEG-silane in comparison to DEG–Gd 2 O 3 . Treatment of DEG–US-Gd 2 O 3 with PEG-silane provides enhanced relaxivity while preventing aggregation of the oxide cores. This study confirms that PEG-covered Gd 2 O 3 nanoparticles can be used for positively contrasted MR applications requiring stability, biocompatible coatings and nanocrystal functionalization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-4484/18/39/395501

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Fortin, M.-A., Petoral Jr, R. M., Söderlind, F., Klasson, A., Engström, M., Veres, T., Käll, P.-O., & Uvdal, K.
Venue
Nanotechnology
Published
2007-09-04
Volume
18
Issue
39
Pages
395501
ISSN
  • 0957-4484 (ISSN-L)
  • 1361-6528
OpenAlex
W2093836608
Cited by
165
References
0
FWCI
5.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Polyethylene glycol-covered ultra-small Gd2O3nanoparticles for positive contrast at 1.5 T magnetic resonance clinical scanning. https://app.cochat.ai/papers/10.1088/0957-4484/18/39/395501
The paper
Fortin, M.-A., Petoral Jr, R. M., Söderlind, F., Klasson, A., Engström, M., Veres, T., Käll, P.-O., & Uvdal, K. (2007). Polyethylene glycol-covered ultra-small Gd2O3nanoparticles for positive contrast at 1.5 T magnetic resonance clinical scanning. Nanotechnology. https://doi.org/10.1088/0957-4484/18/39/395501

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.