Magnetic nanoparticles as gene delivery agents: enhanced transfection in the presence of oscillating magnet arrays
Open accessThe DOI matches its Crossref record.
Abstract
Magnetic nanoparticle-based gene transfection has been shown to be effective in combination with both viral vectors and with non-viral agents. In these systems, therapeutic or reporter genes are attached to magnetic nanoparticles which are then focused to the target site/cells via high-field/high-gradient magnets. The technique has been shown to be efficient and rapid for in vitro transfection and compares well with cationic lipid-based reagents, producing good overall transfection levels with lower doses and shorter transfection times. In spite of its potential advantages (particularly for in vivo targeting), the overall transfection levels do not generally exceed those of other non-viral agents. In order to improve the overall transfection levels while maintaining the advantages inherent in this technique, we have developed a novel, oscillating magnet array system which adds lateral motion to the particle/gene complex in order to promote transfection. Experimental results indicate that the system significantly enhances overall in vitro transfection levels in human airway epithelial cells compared to both static field techniques (p<0.005) and the cationic lipids (p<0.001) tested. In addition, it has the previously demonstrated advantages of magnetofection-rapid transfection times and requiring lower levels of DNA than cationic lipid-based transfection agents. This method shows potential for non-viral gene delivery both in vitro and in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Veiseh, O., Gunn, J. W., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,832
Progress in applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Thanh, N. T. K., Jones, S. K., & Dobson, J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224001 · Cited by 1,455
Self-citationMagnetic nanoparticles for environmental and biomedical applications: a review
Mohammed, L., Gomaa, H. G., Ragab, D., & Zhu, J. (2017) · Particuology · doi:10.1016/j.partic.2016.06.001 · Cited by 682
Magnetic Nanoparticles: From Design and Synthesis to Real World Applications
Kudr, J., Haddad, Y., Richtera, L., Heger, Z., Cernak, M., Adam, V., & Zitka, O. (2017) · Nanomaterials · doi:10.3390/nano7090243 · Cited by 628
Iron Oxide Nanoparticles for Magnetically-Guided and Magnetically-Responsive Drug Delivery
Estelrich, J., Escribano, E., Queralt, J., & Busquets, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16048070 · Cited by 532
Magnetic nanoparticle drug delivery systems for targeting tumor
Mody, V. V., Cox, A., Shah, S., Singh, A., Bevins, W., & Parihar, H. (2014) · Applied Nanoscience · doi:10.1007/s13204-013-0216-y · Cited by 497
Magnetically enhanced nucleic acid delivery. Ten years of magnetofection—Progress and prospects
Plank, C., Zelphati, O., & Mykhaylyk, O. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.08.002 · Cited by 316
Huang, J., Li, Y., Orza, A., Lu, Q., Guo, P., Wang, L., Yang, L., & Mao, H. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504185 · Cited by 292
Synthesis, Functionalization, and Design of Magnetic Nanoparticles for Theranostic Applications
Mosayebi, J., Kiyasatfar, M., & Laurent, S. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700306 · Cited by 241
Sensenig, R., Sapir, Y., MacDonald, C., Cohen, S., & Polyak, B. (2012) · Nanomedicine · doi:10.2217/nnm.12.109 · Cited by 229
Magnetic nanoparticles as targeted delivery systems in oncology
Prijic, S., & Sersa, G. (2011) · Radiology and Oncology · doi:10.2478/v10019-011-0001-z · Cited by 203
Valdiglesias, V., Kiliç, G., Costa, C., Fernández‐Bertólez, N., Pásaro, E., Teixeira, J. P., & Laffon, B. (2015) · Environmental and Molecular Mutagenesis · doi:10.1002/em.21909 · Cited by 181
“For example, ION coated with silica, which achieves the isoelectric point at pH of 2 to 3, are negatively charged at blood pH, helping to avoid aggregate formation in body fluids [McBain et al., 2008].”
BackgroundA Novel Approach for Nucleic Acid Delivery Into Cancer Cells
Vainauska, D., Kozireva, S., Karpovs, A., Čistjakovs, M., & Bariševs, M. (2012) · Medicina · doi:10.3390/medicina48060048 · Cited by 19
“The same approach has also been used in few clinical trials (14, 24, 25).”
BackgroundMethod
Metadata
- Authors
- McBain, S. C., Griesenbach, U., Xenariou, S., Keramane, A., Batich, C. D., Alton, E. W. F. W., & Dobson, J.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2008-08-20
- Volume
- 19
- Issue
- 40
- Pages
- 405102
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2071013932
- Cited by
- 118
- References
- 0
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.