Abstract
In the present work, we demonstrate the potential of double gate junctionless (JL) architecture for enhanced sensitivity for detecting biomolecules in cavity modulated field effect transistors (FETs). The higher values of body factor, achieved in asymmetric gate operation under impact ionization is utilized for enhanced sensing margin which is nearly five times higher than compared to symmetrical mode operation. The intrinsic detection sensitivity is evaluated in terms of threshold voltage change, and the ratio of drain current in the presence and absence of biomolecules in JL nanotransistors. It is shown that asymmetric mode JL transistor achieves a higher degree of detection sensitivity even for a partially filled cavity. The work demonstrates the potential of JL channel architecture for cavity based dielectric modulated FET biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Dielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor
Kannan, N., & Kumar, M. J. (2013) · IEEE Electron Device Letters · doi:10.1109/led.2013.2283858 · Cited by 161
Label-free DNA detection with a nanogap embedded complementary metal oxide semiconductor
Kim, C.-H., Jung, C., Lee, K.-B., Park, H. G., & Choi, Y.-K. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/13/135502 · Cited by 103
Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
Shoorideh, K., & Chui, C. O. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2214221 · Cited by 65
Cited by
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Chakraborty, A., & Sarkar, A. (2017) · Journal of Computational Electronics · doi:10.1007/s10825-017-0999-2 · Cited by 94
Dwivedi, P., & Kranti, A. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2640192 · Cited by 87
“Many transistor topologies such as inversion mode [4]–[11], junctionless [12]–[14], and tunnel [15]–[19] FETs have been investigated for sensing applications.”
BackgroundSelf-citationDas, A., Rewari, S., Kanaujia, B. K., Deswal, S. S., & Gupta, R. S. (2023) · Journal of Computational Electronics · doi:10.1007/s10825-023-02008-w · Cited by 67
Kumar, S., Singh, B., & Singh, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3056385 · Cited by 39
Metadata
- Authors
- Parihar, M. S., & Kranti, A.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2015-03-16
- Volume
- 26
- Issue
- 14
- Pages
- 145201
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2031208395
- Cited by
- 79
- References
- 5
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced sensitivity of double gate junctionless transistor architecture for biosensing applications. https://app.cochat.ai/papers/10.1088/0957-4484/26/14/145201
- The paper
- Parihar, M. S., & Kranti, A. (2015). Enhanced sensitivity of double gate junctionless transistor architecture for biosensing applications. Nanotechnology. https://doi.org/10.1088/0957-4484/26/14/145201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.