Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record.

Determination of the spring constants of probes for force microscopy/spectroscopy

Gibson, Christopher T, Watson, Gregory S, Myhra, Sverre · 1996 · Nanotechnology

Abstract

A direct, accurate and convenient procedure for calibrating the spring constants of probes used for force microscopy/spectroscopy is described. It amounts to deflecting an `unknown' cantilever with a `standard' lever, where the standard lever has been precalibrated. The absolute and relative accuracies of the procedure are - 30% and - 20%, respectively; the former is limited by uncertainties in the determination of the spring constant for the `standard' lever, as well as that for the `unknown'. The method differs from others of the static deflection variety by its exploitation of the routine features of current instruments. The technique is compared with other static and dynamic methods currently being used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0957-4484/7/3/014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 237

Metadata

Authors
Gibson, C. T., Watson, G. S., & Myhra, S.
Venue
Nanotechnology
Published
1996-09-01
Volume
7
Issue
3
Pages
259-262
ISSN
  • 0957-4484 (ISSN-L)
  • 1361-6528
OpenAlex
W1994079521
Cited by
237
References
0
FWCI
1.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of the spring constants of probes for force microscopy/spectroscopy. https://app.cochat.ai/papers/10.1088/0957-4484/7/3/014
The paper
Gibson, C. T., Watson, G. S., & Myhra, S. (1996). Determination of the spring constants of probes for force microscopy/spectroscopy. Nanotechnology. https://doi.org/10.1088/0957-4484/7/3/014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.