The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Normal and torsional spring constants of atomic force microscope cantilevers
Abstract
Two methods commonly used to measure the normal spring constants of atomic force microscope cantilevers are the added mass method of Cleveland et al. [J. P. Cleveland et al., Rev. Sci. Instrum. 64, 403 (1993)], and the unloaded resonance technique of Sader et al. [J. E. Sader, J. W. M. Chon, and P. Mulvaney, Rev. Sci. Instrum. 70, 3967 (1999)]. The added mass method involves measuring the change in resonant frequency of the fundamental mode of vibration upon the addition of known masses to the free end of the cantilever. In contrast, the unloaded resonance technique requires measurement of the unloaded resonant frequency and quality factor of the fundamental mode of vibration, as well as knowledge of the plan view dimensions of the cantilever and properties of the fluid. In many applications, such as frictional force microscopy, the torsional spring constant is often required. Consequently, in this article, we extend both of these techniques to allow simultaneous calibration of both the normal and torsional spring constants. We also investigate the validity and applicability of the unloaded resonance method when a mass is attached to the free end of the cantilever due to its importance in practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A treatise on the mathematical theory of elasticity
Love, A. E. H. (1892) · HAL · Cited by 7,247
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Vibration problems in engineering
Timoshenko, S. P. (1928) · CERN Document Server (European Organization for Nuclear Research) · Cited by 3,449
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Self-citationENCYCLOPEDIA OF Surface and Colloid Science
Somasundaran, P., & Hubbard, A. T. (2021) · CRC Press eBooks · doi:10.1201/9780367813437 · Cited by 2,104
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Self-citationSader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Self-citationMethod for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Self-citationCalibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
Research works printed but not linked: 2
- 2000, Rev. Sci. Instrum., 71, 2746, 10.1063/1.1150686 · doi:10.1063/1.1150686
- 2001, Rev. Sci. Instrum., 72, 4164, 10.1063/1.1406934 · doi:10.1063/1.1406934
Cited by
Modeling and Experimental Characterization of an Untethered Magnetic Micro-Robot
Pawashe, C., Floyd, S., & Sitti, M. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909341413 · Cited by 318
Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
Sader, J. E., Sanelli, J. A., Adamson, B. D., Monty, J. P., Wei, X., Crawford, S. A., Friend, J. R., Marusic, I., Mulvaney, P., & Bieske, E. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4757398 · Cited by 283
Self-citationThe applications of atomic force microscopy to vision science
Last, J. A., Russell, P., Nealey, P. F., & Murphy, C. J. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5470 · Cited by 100
Bennewitz, R. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00845-x · Cited by 60
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
Metadata
- Authors
- Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., & Sader, J. E.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2004-06-01
- Volume
- 75
- Issue
- 6
- Pages
- 1988-1996
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1985393072
- Cited by
- 551
- References
- 21
- FWCI
- 11.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Normal and torsional spring constants of atomic force microscope cantilevers. https://app.cochat.ai/papers/10.1063/1.1753100
- The paper
- Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., & Sader, J. E. (2004). Normal and torsional spring constants of atomic force microscope cantilevers. Review of Scientific Instruments. https://doi.org/10.1063/1.1753100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.