How does a tip tap?
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
There is a demand for good theoretical understanding of the response of an atomic force microscope cantilever to the extremely nonlinear impacts received while tapping a sample. A model and numerical simulations are presented in this paper which provide a very pleasing comparison with experimental results. The dependence of the cantilever amplitude and phase upon the sample stiffness, adhesion and damping are investigated using these simulations, and it is found that `topographic' tapping images are not independent of sample properties, nor will it be trivial to measure materials' properties from the tapping data. The simulation can be applied to other probe microscope configurations as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Surface energy and the contact of elastic solids
Johnson, K. L., Kendall, K., & Roberts, A. D. (1971) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1971.0141 · Cited by 8,061
Yielding of steel sheets containing slits
Dugdale, D. S. (1960) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(60)90013-2 · Cited by 7,766
Effect of contact deformations on the adhesion of particles
Derjaguin, B. V., Muller, V. M., & Toporov, Y. P. (1975) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(75)90018-1 · Cited by 4,589
Adhesion of spheres: The JKR-DMT transition using a dugdale model
Maugis, D. (1992) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(92)90285-t · Cited by 2,066
Atomic Resolution of the Silicon (111)-(7×7) Surface by Atomic Force Microscopy
Giessibl, F. J. (1995) · Science · doi:10.1126/science.267.5194.68 · Cited by 1,189
Fractured polymer/silica fiber surface studied by tapping mode atomic force microscopy
Zhong, Q., Inniss, D., Kjoller, K., & Elings, V. B. (1993) · Surface Science · doi:10.1016/0039-6028(93)90582-5 · Cited by 924
Muller, V. M., Yushchenko, V. S., & Derjaguin, B. V. (1980) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(80)90419-1 · Cited by 738
Fractured polymer/silica fiber surface studied by tapping mode atomic force microscopy
Zhong, Q., Inniss, D., Kjoller, K., & Elings, V. B. (1993) · Surface Science Letters · doi:10.1016/0167-2584(93)90906-y · Cited by 628
Tapping mode atomic force microscopy in liquid
Putman, C. A. J., Van der Werf, K. O., De Grooth, B. G., Van Hulst, N. F., & Greve, J. (1994) · Applied Physics Letters · doi:10.1063/1.111597 · Cited by 545
Cantilever dynamics in quasinoncontact force microscopy: Spectroscopic aspects
Anczykowski, B., Krüger, D., & Fuchs, H. (1996) · Physical review. B, Condensed matter · doi:10.1103/physrevb.53.15485 · Cited by 274
Scanning Force Microscopy in Biology
Bustamante, C., & Keller, D. (1995) · Physics Today · doi:10.1063/1.881478 · Cited by 271
Forces affecting the substrate in resonant tapping force microscopy
Spatz, J. P., Sheiko, S. S., Möller, M., Winkler, R. G., Reineker, P., & Marti, O. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/2/002 · Cited by 148
‘SOFT’ CONTACT PROBLEMS IN LINEAR ELASTICITY
Hughes, B. D., & White, L. R. (1979) · The Quarterly Journal of Mechanics and Applied Mathematics · doi:10.1093/qjmam/32.4.445 · Cited by 125
Driven nonlinear atomic force microscopy cantilevers: From noncontact to tapping modes of operation
Sarid, D., Ruskell, T. G., Workman, R. K., & Chen, D. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.589163 · Cited by 106
Numerical simulations of a scanning force microscope with a large-amplitude vibrating cantilever
Chen, J., Workman, R. K., Sarid, D., & Höper, R. (1994) · Nanotechnology · doi:10.1088/0957-4484/5/4/003 · Cited by 89
High Resolution Images of Cell Surface Using a Tapping-Mode Atomic Force Microscope
Umemura, K., Arakawa, H., & Ikai, A. (1993) · Japanese Journal of Applied Physics · doi:10.1143/jjap.32.l1711 · Cited by 46
Cited by
Energy dissipation in tapping-mode atomic force microscopy
Cleveland, J. P., Anczykowski, B., Schmid, A. E., & Elings, V. B. (1998) · Applied Physics Letters · doi:10.1063/1.121434 · Cited by 881
Jalili, N., & Laxminarayana, K. (2004) · Mechatronics · doi:10.1016/j.mechatronics.2004.04.005 · Cited by 610
Attractive and repulsive tip-sample interaction regimes in tapping-mode atomic force microscopy
García, R., & San Paulo, A. (1999) · Physical Review B · doi:10.1103/physrevb.60.4961 · Cited by 570
Accurate thickness measurement of graphene
Shearer, C. J., Slattery, A. D., Stapleton, A. J., Shapter, J. G., & Gibson, C. T. (2016) · Nanotechnology · doi:10.1088/0957-4484/27/12/125704 · Cited by 496
Capillary forces in tapping mode atomic force microscopy
Zitzler, L., Herminghaus, S., & Mugele, F. (2002) · Physical Review B · doi:10.1103/physrevb.66.155436 · Cited by 305
Metadata
- Authors
- Burnham, N. A., Behrend, O. P., Oulevey, F., Gremaud, G., Gallo, P.-J., Gourdon, D., Dupas, E., Kulik, A. J., Pollock, H. M., & Briggs, G. A. D.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 1997-06-01
- Volume
- 8
- Issue
- 2
- Pages
- 67-75
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2017529573
- Cited by
- 265
- References
- 17
- FWCI
- 20.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.