Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record.

A tapered hollow metallic microneedle array using backside exposure of SU-8

Open access
Kim, Kabseog, Park, Daniel S, Lu, Hong M, Che, Wooseong, Kim, Kyunghwan, Lee, Jeong-Bong, Ahn, Chong H·2004·Journal of Micromechanics and Microengineering

Abstract

This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 mesa was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures, with angles in the range of 3.1°–5°, was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a planarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both 200 µm and 400 µm tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of 33.6–101 µm and wall thickness of 10–20 µm were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single 400 µm tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of 20 µm, a tapered angle of 3.08° and a tip inner diameter of 33.6 µm has a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0960-1317/14/4/021

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Kim, K., Park, D. S., Lu, H. M., Che, W., Kim, K., Lee, J.-B., & Ahn, C. H.
Venue
Journal of Micromechanics and Microengineering
Published
2004-02-06
Volume
14
Issue
4
Pages
597-603
ISSN
  • 0960-1317 (ISSN-L)
  • 1361-6439
OpenAlex
W2134785604
Cited by
210
References
0
FWCI
12.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A tapered hollow metallic microneedle array using backside exposure of SU-8. https://app.cochat.ai/papers/10.1088/0960-1317/14/4/021
The paper
Kim, K., Park, D. S., Lu, H. M., Che, W., Kim, K., Lee, J.-B., & Ahn, C. H. (2004). A tapered hollow metallic microneedle array using backside exposure of SU-8. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/14/4/021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.