A tapered hollow metallic microneedle array using backside exposure of SU-8
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 mesa was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures, with angles in the range of 3.1°–5°, was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a planarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both 200 µm and 400 µm tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of 33.6–101 µm and wall thickness of 10–20 µm were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single 400 µm tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of 20 µm, a tapered angle of 3.08° and a tip inner diameter of 33.6 µm has a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasound-Mediated Transdermal Protein Delivery
Mitragotri, S., Blankschtein, D., & Langer, R. (1995) · Science · doi:10.1126/science.7638603 · Cited by 791 · cited 1×
“Mitragotri et al [3] used low-frequency ultrasound to increase the permeability of human skin by several orders of magnitude compared to the case without ultrasound activation and demonstrated transdermal delivery of high molecular weight proteins such as insulin, interferon gamma and erythropoeitin.”
BackgroundDisposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Self-citationRates of Needle-Stick Injury Caused by Various Devices in a University Hospital
Jagger, J., Hunt, E. H., Brand-Elnaggar, J., & Pearson, R. D. (1988) · New England Journal of Medicine · doi:10.1056/nejm198808043190506 · Cited by 393 · cited 1×
“Conventional hypodermic needles create fear of injection-related pain among patients and there has been increasing concern about the risks of transmitting blood born pathogens such as HIV (human immunodeficiency virus) or hepatitis to health-care workers by accidental needle stick injuries [2].”
BackgroundSilicon-processed microneedles
Lin, L., & Pisano, A. P. (1999) · Journal of Microelectromechanical Systems · doi:10.1109/84.749406 · Cited by 250 · cited 1×
“Lin and Pisano [ 6 ] demonstrated 1, 3 and 6 mm long single hollow silicon hypodermic microneedles with fully enclosed fluidic channels.”
BackgroundEncyclopedia of Medical History
McGrew, R. E. (1985) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-05429-9 · Cited by 189
Encyclopedia of Medical History
Stowe, S. M., & McGrew, R. E. (1986) · The History Teacher · doi:10.2307/493391 · Cited by 105
Zimmermann, S., Fienbork, D., Stoeber, B., Flounders, A. W., & Liepmann, D. (2004) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2003.1215262 · Cited by 63 · cited 1×
“Zimmermann et al [8] demonstrated a disposable self-calibrating continuous glucose monitor using hollow microneedles with a porous poly-Si dialysis membrane and enzyme-based flow-through sensor.”
Background
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477
Recent advances of microneedles for biomedical applications: drug delivery and beyond
Yang, J., Liu, X., Fu, Y., & Song, Y. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.03.007 · Cited by 378
Hollow microneedles: A perspective in biomedical applications
Cárcamo-Martínez, Á., Mallon, B., Domínguez-Robles, J., Vora, L. K., Anjani, Q. K., & Donnelly, R. F. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120455 · Cited by 285
Insulin delivery systems combined with microneedle technology
Jin, X., Zhu, D. D., Chen, B. Z., Ashfaq, M., & Guo, X. D. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.03.011 · Cited by 275
Fabrication of multi-layer SU-8 microstructures
Mata, A., Fleischman, A. J., & Roy, S. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/2/012 · Cited by 237
Microneedles for transdermal diagnostics: Recent advances and new horizons
Liu, G.-S., Kong, Y., Wang, Y., Luo, Y., Fan, X., Xie, X., Yang, B.-R., & Wu, M. X. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119740 · Cited by 231
“Shorter length provides MNs with higher yield strength and shear capacity [92,93], so the short MNs for ISF sampling have greater flexibility in design and material selection.”
BackgroundDesign, fabrication and characterization of drug delivery systems based on lab-on-a-chip technology
Nguyen, N.-T., Shaegh, S. A. M., Kashaninejad, N., & Phan, D.-T. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.008 · Cited by 210
“Materials suitable for making microneedles are silicon [157-163], metal [164, 165], polymer [166-172] and ceramic [173-175].”
BackgroundDrawing Lithography: Three‐Dimensional Fabrication of an Ultrahigh‐Aspect‐Ratio Microneedle
Lee, K., Lee, H. C., Lee, D., & Jung, H. (2010) · Advanced Materials · doi:10.1002/adma.200902418 · Cited by 208
The Role of 3D Printing Technology in Microengineering of Microneedles
Detamornrat, U., McAlister, E., Hutton, A. R. J., Larrañeta, E., & Donnelly, R. F. (2022) · Small · doi:10.1002/smll.202106392 · Cited by 199
Drawing lithography for microneedles: A review of fundamentals and biomedical applications
Lee, K., & Jung, H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.065 · Cited by 185
“Various hollow microneedles have been fabricated using subtractive processes such as photolithography [51], deep reactive etching [46e49,52e54] and deep X-ray lithography of Lithographie, Galvanoformung, and Abformung (LIGA) [50,55e57] which are microfabrications to engrave 3D structural shape as the required pattern…”
MethodEsch, M. B., Sung, J. H., Yang, J., Yu, C., Yu, J., March, J. C., & Shuler, M. L. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9669-0 · Cited by 179
“Partial SU-8 exposure has been previously used to fabricate microelectromechnical systems (MEMS) (Carlier et al. 2004; Kim et al. 2004) and structures that have been used asmolds for complex microfluidic PDMS devices (Anderson et al. 2000; Bohl et al. 2005).”
The use of high aspect ratio photoresist (SU-8) for super-hydrophobic pattern prototyping
Shirtcliffe, N. J., Aqil, S., Evans, C., McHale, G., Newton, M. I., Perry, C. C., & Roach, P. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/10/013 · Cited by 171
“Negative sidew alls or T-topping, producing mushroom shaped pillars can a problem with this res ist, but this effect can be utilised in some devices [9].”
BackgroundMultidirectional UV Lithography for Complex 3-D MEMS Structures
Yoon, Y.-K., Park, J.-H., & Allen, M. G. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.879669 · Cited by 160
“A schematic viewgraph of this reverse-side exposure approach is shown in Fig. 1(b) [8]–[ 10 ].”
MethodXiang, Z., Liu, J., & Lee, C. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.12 · Cited by 100
Varying-Length Polymer Microneedle Arrays Fabricated by Droplet Backside Exposure
Kwon, K. Y., Weber, A., & Li, W. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2352412 · Cited by 23
“Metal microneedles were developed using electroplating onto a seed layer sputtered on polymer micromolds [12].”
Method
Metadata
- Authors
- Kim, K., Park, D. S., Lu, H. M., Che, W., Kim, K., Lee, J.-B., & Ahn, C. H.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2004-02-06
- Volume
- 14
- Issue
- 4
- Pages
- 597-603
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2134785604
- Cited by
- 210
- References
- 7
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.