Rapid prototyping of microfluidic chips in COC
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We present a novel, cost-efficient process chain for fast tooling and small-lot replication of high-quality, multi-scale microfluidic polymer chips within less than 5 days. The fabrication chain starts with a primary master which is made by well-established cleanroom processes such as DRIE or negative SU-8 resist based surface micromachining. The formation of undercuts in the master which would complicate demolding is carefully avoided. Secondary PDMS masters or epoxy-based masters which are more suitable for common polymer replication schemes such as soft-embossing, hot-embossing or injection molding are subsequently cast from the primary masters. The polymer replica are mainly made of COC and show excellent fidelity with the conventionally micromachined master while displaying no degeneration, even after more than 200 cycles. The use of other polymers such as PMMA is also possible. The process chain further includes surface modification techniques for overall, long-term stable hydrophilic coatings and for local hydrophobic patches as well as a durable sealing based on thermal bonding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131 · cited 1×
“Due to their interesting material characteristics in terms of flexibility, transparency and self-adhesive properties [35, 36], elastomers such as poly-dimethyl siloxane (PDMS) [37, 38] are nowadays widely used in the microfluidics community.”
BackgroundSU-8: a low-cost negative resist for MEMS
Lorenz, H., Despont, M., Fahrni, N., LaBianca, N., Renaud, P., & Vettiger, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/010 · Cited by 979 · cited 2×
“The following process parameters are applicable to thicknesses of composite layers of SU-8 2100 [30] and SU-8 2025 [14, 31] up to 300 μm.”
BackgroundMethodReview on micro molding of thermoplastic polymers
Heckele, M., & Schomburg, W. K. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/3/r01 · Cited by 915 · cited 1×
“This trend to use polymer chips in microfluidics is driven by costefficient replication techniques such as hot embossing [1–4, 8] or injection molding [5–10] as well as the huge variety and the favorable pricing of polymers [11].”
MethodPolymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Hot embossing as a method for the fabrication of polymer high aspect ratio structures
Becker, H., & Heim, U. (2000) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(00)00296-x · Cited by 666 · cited 1×
“This trend to use polymer chips in microfluidics is driven by costefficient replication techniques such as hot embossing [1–4, 8] or injection molding [5–10] as well as the huge variety and the favorable pricing of polymers [11].”
MethodHigh-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Lab-on-a-Chip: A Revolution in Biological and Medical Sciences.
Figeys, D., & Pinto, D. (2000) · Analytical Chemistry · doi:10.1021/ac002800y · Cited by 562 · cited 1×
“This work focuses on the prototyping of polymer disks in a standard 12-cm compact disc (CD) format for lab-on-a-disk [19–22] systems or other lab-on-a-chip substrates possessing comparatively large surface areas [23–25].”
BackgroundMicrofabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478 · cited 1×
“This work focuses on the prototyping of polymer disks in a standard 12-cm compact disc (CD) format for lab-on-a-disk [19–22] systems or other lab-on-a-chip substrates possessing comparatively large surface areas [23–25].”
BackgroundHot embossing - The molding technique for plastic microstructures
Heckele, M., Bacher, W., & Müller, K. D. (1998) · Microsystem Technologies · doi:10.1007/s005420050112 · Cited by 281 · cited 1×
“This trend to use polymer chips in microfluidics is driven by costefficient replication techniques such as hot embossing [1–4, 8] or injection molding [5–10] as well as the huge variety and the favorable pricing of polymers [11].”
MethodDesign and Fabrication of CD-like Microfluidic Platforms for Diagnostics: Microfluidic Functions
Madou, M. J., Lee, L. J., Daunert, S., Lai, S., & Shih, C. (2001) · Biomedical Microdevices · doi:10.1023/a:1011419515576 · Cited by 239
Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding
Kim, D. S., Lee, S. H., Ahn, C. H., Lee, J. Y., & Kwon, T. H. (2006) · Lab on a Chip · doi:10.1039/b516495h · Cited by 185
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Self-citationPolymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Bonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices
Guckenberger, D. J., de Groot, T. E., Wan, A. M. D., Beebe, D. J., & Young, E. W. K. (2015) · Lab on a Chip · doi:10.1039/c5lc00234f · Cited by 513
Metadata
- Authors
- Steigert, J., Haeberle, S., Brenner, T., Müller, C., Steinert, C. P., Koltay, P., Gottschlich, N., Reinecke, H., Rühe, J., Zengerle, R., & Ducrée, J.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2007-01-11
- Volume
- 17
- Issue
- 2
- Pages
- 333-341
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2139893885
- Cited by
- 194
- References
- 14
- FWCI
- 11.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.