A low temperature surface modification assisted method for bonding plastic substrates
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
A low cost, low temperature process for sealing microfluidic devices composed of at least one organic polymeric substrate is presented. The process is based on the surface modification of the organic substrate by means of a silane solution, resulting in irreversible bonding. It is a generic method of bonding polymeric/plastic substrates, bare or structured ones, such as poly(methylmethacrylate) (PMMA), polystyrene (PS) or epoxy-type polymers, to Si-containing substrates, such as poly(dimethylsiloxane) (PDMS), Si and glass. In the case that bonding between organic polymer (PMMA, PS, etc) substrates is desired, an intermediate thin PDMS layer is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spectrometric Identification of Organic Compounds
Silverstein, R. M., & Bassler, G. C. (1962) · Journal of Chemical Education · doi:10.1021/ed039p546 · Cited by 14,272
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795 · cited 2×
“In addition to the cost of the required equipment, the methods requiring pressure application are advisable for designs with comparatively small structured areas in comparison to the whole chip area [3].”
BackgroundMethodDetermining the optimal PDMS–PDMS bonding technique for microfluidic devices
Eddings, M. A., Johnson, M. A., & Gale, B. K. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/067001 · Cited by 567
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503 · cited 1×
“Silicon (Si) and glass were the first substrates used for the fabrication of microfluidic devices, because the existing processing technology used to create such devices was well established in the microelectronics industry [2].”
MethodSurface Modification of Poly(methyl methacrylate) Used in the Fabrication of Microanalytical Devices
Henry, A. C., Tutt, T. J., Galloway, M., Davidson, Y. Y., McWhorter, C. S., Soper, S. A., & McCarley, R. L. (2000) · Analytical Chemistry · doi:10.1021/ac000685l · Cited by 319
Siqueira Petri, D. F., Wenz, G., Schunk, P., & Schimmel, T. (1999) · Langmuir · doi:10.1021/la981379u · Cited by 238
Blanco, F. J., Agirregabiria, M., Garcia, J., Berganzo, J., Tijero, M., Arroyo, M. T., Ruano, J. M., Aramburu, I., & Mayora, K. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/7/027 · Cited by 170
Cited by
Lab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
In-package atmospheric pressure cold plasma treatment of strawberries
Misra, N. N., Patil, S., Moiseev, T., Bourke, P., Mosnier, J. P., Keener, K. M., & Cullen, P. J. (2014) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2013.10.023 · Cited by 386
A facile route for irreversible bonding of plastic-PDMS hybrid microdevices at room temperature
Tang, L., & Lee, N. Y. (2010) · Lab on a Chip · doi:10.1039/b924753j · Cited by 267
Pesticide degradation in water using atmospheric air cold plasma
Sarangapani, C., Misra, N. N., Milosavljevic, V., Bourke, P., O’Regan, F., & Cullen, P. J. (2016) · Journal of Water Process Engineering · doi:10.1016/j.jwpe.2016.01.003 · Cited by 236
“Until recently, industrial applications of plasma were mostly confined to material processing and electronics, including etching and deposition, bonding of plastics, and textile dying [21–23].”
PDMS Bonding Technologies for Microfluidic Applications: A Review
Borók, A., Laboda, K., & Bonyár, A. (2021) · Biosensors · doi:10.3390/bios11080292 · Cited by 225
Simple room temperature bonding of thermoplastics and poly(dimethylsiloxane)
Sunkara, V., Park, D.-K., Hwang, H., Chantiwas, R., Soper, S. A., & Cho, Y.-K. (2011) · Lab Chip · doi:10.1039/c0lc00272k · Cited by 185
Tsougeni, K., Papageorgiou, D., Tserepi, A., & Gogolides, E. (2010) · Lab Chip · doi:10.1039/b916566e · Cited by 179
Self-citationSoft curvature sensors for joint angle proprioception
Kramer, R. K., Majidi, C., Sahai, R., & Wood, R. J. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094701 · Cited by 174
“Flexible circuits are bonded to PDMS films through an amino-epoxy chemical bonding method [20], [21].”
MethodMehta, V., & Rath, S. N. (2021) · Bio-Design and Manufacturing · doi:10.1007/s42242-020-00112-5 · Cited by 163
Irreversible, direct bonding of nanoporous polymer membranes to PDMS or glass microdevices
Aran, K., Sasso, L. A., Kamdar, N., & Zahn, J. D. (2010) · Lab on a Chip · doi:10.1039/b924816a · Cited by 159
Flexible and multi-directional piezoelectric energy harvester for self-powered human motion sensor
Kim, M.-O., Pyo, S., Oh, Y., Kang, Y., Cho, K.-H., Choi, J., & Kim, J. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aaa722 · Cited by 81
“Then, the PDMS bump and frame were covalently bonded to PVDF film using 3-aminopropyltriethoxysilane (3-APTES) -based bonding [29].”
Method
Metadata
- Authors
- Vlachopoulou, M.-E., Tserepi, A., Pavli, P., Argitis, P., Sanopoulou, M., & Misiakos, K.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2008-11-27
- Volume
- 19
- Issue
- 1
- Pages
- 015007
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2052155987
- Cited by
- 164
- References
- 13
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.