Patterning conductive PDMS nanocomposite in an elastomer using microcontact printing
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
This paper introduces a simple method of embedding conductive and flexible elastomer micropatterns into a bulk elastomer. Employing microcontact printing and cast molding techniques, patterns consisting of conductive poly(dimethylsiloxane) (PDMS) composites mixed with multi-walled carbon nanotubes (MWCNTs) are embedded into bulk PDMS to form all-elastomer devices. To pattern conductive composites, a micromachined printing mold is utilized to transfer composite ink from a spin-coated thin layer to another substrate. Distinct from previously reported approaches, the printing mold in this technique, once fabricated, can be repeatedly used to generate new patterns and therefore greatly simplifies the device fabrication process and improves its efficiency. Manufactured devices with embedded conductive patterns exhibit excellent mechanical flexibility. With characterization of printing reliability, electrical conductivity of the composites is also shown with different loading percentages of MWCNTs. Furthermore, a simple strain gauge was fabricated and tested to demonstrate the potential applications of embedded conductive patterns. Overall, this approach demonstrates feasibility to be a simple method to pattern conductive elastomers that work as electrodes or sensing probes in PDMS-based devices. With further development, this technology yields many potential applications in lab-on-a-chip systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Load transfer and deformation mechanisms in carbon nanotube-polystyrene composites
Qian, D., Dickey, E. C., Andrews, R., & Rantell, T. (2000) · Applied Physics Letters · doi:10.1063/1.126500 · Cited by 2,455 · cited 8×
“After toluene reached full evaporation overnight, the PDMS curing agent (1:10 weight ratio to base polymer) was added into the mixture and conductive PDMS–MWCNTs composites were ready to work as printing ink.”
MethodInfluentialPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Patterning Self-Assembled Monolayers: Applications in Materials Science
Kumar, A., Biebuyck, H. A., & Whitesides, G. M. (1994) · Langmuir · doi:10.1021/la00017a030 · Cited by 1,114
Polymers for flexible displays: From material selection to device applications
Choi, M.-C., Kim, Y., & Ha, C.-S. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.11.004 · Cited by 981
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
Characterizing and Patterning of PDMS‐Based Conducting Composites
Niu, X. Z., Peng, S. L., Liu, L. Y., Wen, W. J., & Sheng, P. (2007) · Advanced Materials · doi:10.1002/adma.200602515 · Cited by 414
Aligned Carbon Nanotube−Polymer Hybrid Architectures for Diverse Flexible Electronic Applications
Jung, Y. J., Kar, S., Talapatra, S., Soldano, C., Viswanathan, G., Li, X., Yao, Z., Ou, F. S., Avadhanula, A., Vajtai, R., et al. (2006) · Nano Letters · doi:10.1021/nl052238x · Cited by 316 · cited 1×
“potential cracking problem when bent or stressed [7], which is undesirable in many flexible electronics applications [9, 10].”
BackgroundRecent advances in microcontact printing
Quist, A. P., Pavlovic, E., & Oscarsson, S. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2847-z · Cited by 292
Microsolidics: Fabrication of Three‐Dimensional Metallic Microstructures in Poly(dimethylsiloxane)
Siegel, A. C., Bruzewicz, D. A., Weibel, D. B., & Whitesides, G. M. (2007) · Advanced Materials · doi:10.1002/adma.200601787 · Cited by 212
Lundberg, B., & Sundqvist, B. (1986) · Journal of Applied Physics · doi:10.1063/1.337401 · Cited by 205 · cited 1×
“Interestingly, since higher voltages could produce more Joule heating and cause sample temperature to rise, conductivity should typically decrease [11, 13].”
BackgroundPhotopatternable Conductive PDMS Materials for Microfabrication
Cong, H., & Pan, T. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701437 · Cited by 191 · cited 1×
“In another approach, photosensitive chemical agents were added into the conductive composite converting it into a photopatternable resist [18].”
BackgroundLee, K. J., Fosser, K. A., & Nuzzo, R. G. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400189 · Cited by 112
Lim, K. S., Chang, W.-J., Koo, Y.-M., & Bashir, R. (2006) · Lab on a Chip · doi:10.1039/b514755g · Cited by 77
Study of piezoresistance effect of carbon nanotube-PDMS composite materials for nanosensors
Lu, J.-Y., Lü, M., Bermak, A., & Lee, Y.-K. (2007) · IEEE Conference on Nanotechnology (IEEE NANO) · doi:10.1109/nano.2007.4601407 · Cited by 67 · cited 1×
“Interestingly, since higher voltages could produce more Joule heating and cause sample temperature to rise, conductivity should typically decrease [11, 13].”
BackgroundNanofabrication with molds & stamps
Gates, B. D. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00701-7 · Cited by 54
Cited by
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite
Amjadi, M., Pichitpajongkit, A., Lee, S., Ryu, S., & Park, I. (2014) · ACS Nano · doi:10.1021/nn501204t · Cited by 2,350
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Ultra-stretchable and skin-mountable strain sensors using carbon nanotubes–Ecoflex nanocomposites
Amjadi, M., Yoon, Y. J., & Park, I. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/37/375501 · Cited by 817
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Metadata
- Authors
- Liu, C.-X., & Choi, J.-W.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2009-07-14
- Volume
- 19
- Issue
- 8
- Pages
- 085019
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2156471291
- Cited by
- 186
- References
- 17
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.