The DOI matches its Crossref record.
Real-time measurement of the three-axis contact force distribution using a flexible capacitive polymer tactile sensor
Open accessAbstract
In this paper, we report real-time measurement results of various contact forces exerted on a new flexible capacitive three-axis tactile sensor array based on polydimethylsiloxane (PDMS). A unit sensor consists of two thick PDMS layers with embedded copper electrodes, a spacer layer, an insulation layer and a bump layer. There are four capacitors in a unit sensor to decompose a contact force into its normal and shear components. They are separated by a wall-type spacer to improve the mechanical response time. Four capacitors are arranged in a square form. The whole sensor is an 8 _ 8 array of unit sensors and each unit sensor responds to forces in all three axes. Measurement results show that the full-scale range of detectable force is around 0–20 mN (250 kPa) for all three axes. The estimated sensitivities of a unit sensor with the current setup are 1.3, 1.2 and 1.2%/mN for the x- , y- and z -axes, respectively. A simple mechanical model has been established to calculate each axial force component from the measured capacitance value. Normal and shear force distribution images are captured from the fabricated sensor using a real-time measurement system. The mechanical response time of a unit sensor has been estimated to be less than 160 ms. The flexibility of the sensor has also been demonstrated by operating the sensor on a curved surface of 4 mm radius of curvature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Recent Progress in Electronic Skin
Wang, X., Dong, L., Zhang, H., Yu, R., Pan, C., & Wang, Z. L. (2015) · Advanced Science · doi:10.1002/advs.201500169 · Cited by 976
Park, J., Lee, Y., Hong, J., Lee, Y., Ha, M., Jung, Y., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn505953t · Cited by 649
The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies
Ward-Cherrier, B., Pestell, N., Cramphorn, L., Winstone, B., Giannaccini, M. E., Rossiter, J., & Lepora, N. F. (2018) · Soft Robotics · doi:10.1089/soro.2017.0052 · Cited by 587
Recent Progress in Advanced Tactile Sensing Technologies for Soft Grippers
Qu, J., Mao, B., Li, Z., Xu, Y., Zhou, K., Cao, X., Fan, Q., Xu, M., Liang, B., Liu, H., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202306249 · Cited by 259
Metadata
- Authors
- Lee, H.-K., Chung, J., Chang, S.-I., & Yoon, E.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2011-02-08
- Volume
- 21
- Issue
- 3
- Pages
- 035010
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2122169310
- Cited by
- 187
- References
- 0
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time measurement of the three-axis contact force distribution using a flexible capacitive polymer tactile sensor. https://app.cochat.ai/papers/10.1088/0960-1317/21/3/035010
- The paper
- Lee, H.-K., Chung, J., Chang, S.-I., & Yoon, E. (2011). Real-time measurement of the three-axis contact force distribution using a flexible capacitive polymer tactile sensor. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/21/3/035010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.