Post-discharge gas composition of a large-gap DBD in humid air by UV–Vis absorption spectroscopy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Large gap dielectric barrier discharges (DBD) provide non-thermal, non-equilibrium plasmas that can generate specific gas chemistry with enhanced bactericidal effects when working in humid air. The present study investigates the post-discharge gas composition of such plasmas operated in humid air using UV–Vis (200–800 nm) absorption spectroscopy. Absorbance spectra have been de-convoluted using direct deconvolution and iterative methods and results are correlated to the DBD electrical parameters. The high-voltage (56 and 70 kV rms) DBD plasma generated at 50 Hz frequency in a closed container over a 20 mm gap in air with relative humidity (RH) of 5–70% has been characterized by I – V and capacitive methods. The post-discharge gas composition at each RH is assessed by UV–Vis absorption spectroscopy for plasma exposure times of 15–120 s. The concentration of ozone and nitrogen oxides (O 3 , NO 2 , NO 3 , N 2 O 4 ) increases with plasma exposure time but a strong decrease in [O 3 ] levels is obtained with increase in RH. The decrease in [O 3 ] and an abundance of nitrogen oxides is ascribed to high specific power densities in the closed container and to increasing RH levels. The absorbance residual following deconvolution shows a strong band at 230–270 nm consistent with the presence of pernitric acid (HNO 4 ) and other HNO x ( x = 1, 3) species. Humid air large gap DBD plasmas in closed containers generate along with O 3 , high levels of nitrogen oxides and HNO x ( x = 1, 4) acids leading to increased bactericidal rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Room-temperature atmospheric pressure plasma plume for biomedical applications
Laroussi, M., & Lu, X. (2005) · Applied Physics Letters · doi:10.1063/1.2045549 · Cited by 637
Cited by
Lu, X., Naidis, G. V., Laroussi, M., Reuter, S., Graves, D. B., & Ostrikov, K. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.03.003 · Cited by 1,230
Brandenburg, R. (2017) · Plasma Sources Science and Technology · doi:10.1088/1361-6595/aa6426 · Cited by 802
Han, L., Patil, S., Boehm, D., Milosavljević, V., Cullen, P. J., & Bourke, P. (2016) · Applied and Environmental Microbiology · doi:10.1128/aem.02660-15 · Cited by 435
Self-citationCold plasma interactions with enzymes in foods and model systems
Misra, N. N., Pankaj, S. K., Segat, A., & Ishikawa, K. (2016) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2016.07.001 · Cited by 422
Self-citationMisra, N. N., Yadav, B., Roopesh, M. S., & Jo, C. (2019) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12398 · Cited by 361
Self-citation
Metadata
- Authors
- Moiseev, T., Misra, N. N., Patil, S., Cullen, P. J., Bourke, P., Keener, K. M., & Mosnier, J. P.
- Venue
- Plasma Sources Science and Technology
- Publisher
- IOP Publishing
- Published
- 2014-10-20
- Volume
- 23
- Issue
- 6
- Pages
- 065033
- ISSN
- 0963-0252 (ISSN-L)
- 1361-6595
- OpenAlex
- W2132318946
- Cited by
- 147
- References
- 1
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Post-discharge gas composition of a large-gap DBD in humid air by UV–Vis absorption spectroscopy. https://app.cochat.ai/papers/10.1088/0963-0252/23/6/065033
- The paper
- Moiseev, T., Misra, N. N., Patil, S., Cullen, P. J., Bourke, P., Keener, K. M., & Mosnier, J. P. (2014). Post-discharge gas composition of a large-gap DBD in humid air by UV–Vis absorption spectroscopy. Plasma Sources Science and Technology. https://doi.org/10.1088/0963-0252/23/6/065033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.