The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Numerical and experimental study of the dynamics of a μ s helium plasma gun discharge with various amounts of N2admixture
Abstract
This paper presents a combined 2D numerical and experimental study of the influence of admixture on the dynamics of a He– discharge in the 10 cm long dielectric tube of a plasma gun set-up. First, the comparison between experiments and simulations is carried out on the ionization front propagation velocity in the tube. The importance of taking into account a detailed kinetic scheme for the He– mixture in the simulations to obtain a good agreement with the experiments is put forward. For the μ s driven plasma gun, the two- and three-body Penning reactions occurring in the plasma column behind the ionization front, are shown to play a key role on the discharge dynamics. In the experiments and simulations, the significant influence of the amplitude of the applied voltage on the ionization front propagation velocity is observed. As the amount of varies, simulation results show that the ionization front velocity, depends on a complex coupling between the kinetics of the discharge, the photoionization and the 2D structure of the discharge in the tube. Finally, the time evolution of axial and radial components of the electric field measured by an electro-optic probe set outside the tube are compared with simulation results. A good agreement is obtained on both components of the electric field. In the tube, simulations show that the magnitude of the axial electric field on the discharge axis depends weakly on the amount of conversely to the magnitude of the off-axis peak electric field. Both, simulations and first measurements in the tube or within the plasma plume show peak electric fields of the order of 45 kV·cm −1 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hagelaar, G. J. M., & Pitchford, L. C. (2005) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/14/4/011 · Cited by 3,422 · cited 1×
“These coefficients are taken from BOLSIG + (Hagelaar and Pitchford 2005) with the IST-Lisbon database (2014).”
MethodZhang, Q., Zhuang, J., von Woedtke, T., Kolb, J. F., Zhang, J., Fang, J., & Weltmann, K.-D. (2014) · Applied Physics Letters · doi:10.1063/1.4895731 · Cited by 73
Cited by
Reuter, S., von Woedtke, T., & Weltmann, K.-D. (2018) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aab3ad · Cited by 522
Zhao, Y., Shao, L., Jia, L., Zou, B., Dai, R., Li, X., & Jia, F. (2022) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2022.103051 · Cited by 38
Metadata
- Authors
- Bourdon, A., Darny, T., Pechereau, F., Pouvesle, J.-M., Viegas, P., Iséni, S., & Robert, E.
- Venue
- Plasma Sources Science and Technology
- Publisher
- IOP Publishing
- Published
- 2016-03-23
- Volume
- 25
- Issue
- 3
- Pages
- 035002
- ISSN
- 0963-0252 (ISSN-L)
- 1361-6595
- OpenAlex
- W2321805940
- Cited by
- 183
- References
- 2
- FWCI
- 11.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Numerical and experimental study of the dynamics of a μ s helium plasma gun discharge with various amounts of N2admixture. https://app.cochat.ai/papers/10.1088/0963-0252/25/3/035002
- The paper
- Bourdon, A., Darny, T., Pechereau, F., Pouvesle, J.-M., Viegas, P., Iséni, S., & Robert, E. (2016). Numerical and experimental study of the dynamics of a μ s helium plasma gun discharge with various amounts of N2admixture. Plasma Sources Science and Technology. https://doi.org/10.1088/0963-0252/25/3/035002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.