Optimizing layout of obstacles for enhanced mixing in microchannels
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
To improve mixing, obstacles have been placed in the channel to try to disrupt flow and reduce the diffusion path. The disruption to flow velocity field alters the flow direction from one fluid to another. In this way, convection may occur to enhance the mixing. Ideally, properly designed geometric parameters, such as layout and number of obstacles, improve the mixing performance without increasing the pressure drop. In this work, CoventorWare TM , a commercial computational fluid dynamics tool for microfluidics was used to study the mixing of two liquids in a 'Y' channel. The results indicate that asymmetric layout of the obstacle has more effect on the mixing than the number of obstacles. Placing obstacles in the microchannels is a novel method for mixing in microfluidic devices, and the results can provide useful information in the design of these devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Einstein, A. (1905) · Annalen der Physik · doi:10.1002/andp.19053220806 · Cited by 8,265
Purcell, E. M. (1977) · American Journal of Physics · doi:10.1119/1.10903 · Cited by 4,360 · cited 5×
“The ratio of convection time tc to molecular diffusion tD is DluPe c /= (5) where Pe was called Stirring number by Purcell and referred to as the Peclet number in the literature.”
BackgroundInfluentialChaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
Generation of Solution and Surface Gradients Using Microfluidic Systems
Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000600b · Cited by 963 · cited 1×
“Figure 6 Evolution of design with obstacles in the Y-channel To evaluate the performance of mixing, mixing efficiency can be calculated by equation 16 [21],”
MethodHydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887 · cited 2×
“[2] used ultrasonic waves to enhance mixing, and Knight [3] described fast mixing by forming and controlling nanoscale, submerged fluids jets.”
MethodQuantitative Analysis of Molecular Interaction in a Microfluidic Channel: The T-Sensor
Kamholz, A. E., Weigl, B. H., Finlayson, B. A., & Yager, P. (1999) · Analytical Chemistry · doi:10.1021/ac990504j · Cited by 631 · cited 1×
“The fluid close to the wall will have more time to mix [16-19].”
BackgroundMicroreactors: New Technology for Modern Chemistry
Ehrfeld, W., Hessel, V., & Löwe, H. (2000) · Cited by 619
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547 · cited 1×
“[10] reported similar structures machined by Excimer laser to achieve rapid mixing.”
MethodIsmagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A. (2000) · Applied Physics Letters · doi:10.1063/1.126351 · Cited by 540
Biotechnology at low Reynolds numbers
Brody, J. P., Yager, P., Goldstein, R. E., & Austin, R. H. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79538-3 · Cited by 523 · cited 2×
“Diffusion is a slow process for mixing, even in a microscaled device [1].”
BackgroundA rapid diffusion immunoassay in a T-sensor
Hatch, A., Kamholz, A. E., Hawkins, K. R., Munson, M. S., Schilling, E. A., Weigl, B. H., & Yager, P. (2001) · Nature Biotechnology · doi:10.1038/88135 · Cited by 383 · cited 1×
“The fluid close to the wall will have more time to mix [16-19].”
BackgroundTheoretical Analysis of Molecular Diffusion in Pressure-Driven Laminar Flow in Microfluidic Channels
Kamholz, A. E., & Yager, P. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76003-1 · Cited by 249 · cited 1×
“Clearly, the large height to width aspect ratio is not welcomed due to uneven distribution of the diffusion along detection section [20].”
BackgroundMicrofluidic Devices for Electrokinetically Driven Parallel and Serial Mixing
Jacobson, S. C., McKnight, T. E., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990576a · Cited by 233
A Picoliter-Volume Mixer for Microfluidic Analytical Systems
He, B., Burke, B. J., Zhang, X., Zhang, R., & Regnier, F. E. (2001) · Analytical Chemistry · doi:10.1021/ac000850x · Cited by 200
Cited by
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Micromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
A State-of-the-Art Review of Mixing in Microfluidic Mixers
Mansur, E. A., YE, M., WANG, Y., & DAI, Y. (2008) · Chinese Journal of Chemical Engineering · doi:10.1016/s1004-9541(08)60114-7 · Cited by 197
A Review of Passive Micromixers with a Comparative Analysis
Raza, W., Hossain, S., & Kim, K.-Y. (2020) · Micromachines · doi:10.3390/mi11050455 · Cited by 182
“Mechanical stirri g is not an effective method for enhancing mixing [36] because the secondary flow is hardly induced in this range.”
Method
Metadata
- Authors
- Wang, H., Iovenitti, P., Harvey, E., & Masood, S.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2002-09-13
- Volume
- 11
- Issue
- 5
- Pages
- 662-667
- ISSN
- 0964-1726 (ISSN-L)
- OpenAlex
- W2095171984
- Cited by
- 238
- References
- 15
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.