The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Generation of Solution and Surface Gradients Using Microfluidic Systems
Abstract
This paper describes a simple, versatile method of generating gradients in composition in solution or on surfaces using microfluidic systems. This method is based on controlled diffusive mixing of species in solutions that are flowing laminarly, at low Reynolds number, inside a network of microchannels. We demonstrate the use of this procedure to generate (1) gradients in the compositions of solutions, measured directly by colorimetric assays and (2) gradients in topography of the surfaces produced by generating concentration gradients of etching reagents, and then using these gradients to etch profiles into the substrate. The lateral dimensions of the gradients examined here, which went from 350 to 900 μm, are determined by the width of the microchannels. Gradients of different size, resolution, and shape have been generated using this method. The shape of the gradients can be changed continuously (dynamic gradients) by varying the relative flow velocities of the input streams of fluids. The method is experimentally simple and highly adaptable, and requires no special equipment except for an elastomeric relief structure that can be readily prepared by rapid prototyping. This technique provides a new platform with which to study phenomena that depend on gradients in concentration, especially dynamic phenomena in cell biology (chemotaxis and haptotaxis) and surface chemistry (nucleation and growth of crystals, etching, and Marangoni effects).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Notch Signaling: Cell Fate Control and Signal Integration in Development
Artavanis-Tsakonas, S., Rand, M. D., & Lake, R. J. (1999) · Science · doi:10.1126/science.284.5415.770 · Cited by 5,909
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Self-citationParent, C. A., & Devreotes, P. N. (1999) · Science · doi:10.1126/science.284.5415.765 · Cited by 890
Control of crystal nucleation by patterned self-assembled monolayers
Aizenberg, J., Black, A. J., & Whitesides, G. M. (1999) · Nature · doi:10.1038/19047 · Cited by 853
Self-citationAizenberg, J., Black, A. J., & Whitesides, G. M. (1999) · Journal of the American Chemical Society · doi:10.1021/ja984254k · Cited by 491
Self-citationComplete asymmetric induction of supramolecular chirality in a hydrogen-bonded assembly
Prins, L. J., Huskens, J., de Jong, F., Timmerman, P., & Reinhoudt, D. N. (1999) · Nature · doi:10.1038/19053 · Cited by 481
Spatial control of actin polymerization during neutrophil chemotaxis
Weiner, O. D., Servant, G., Welch, M. D., Mitchison, T. J., Sedat, J. W., & Bourne, H. R. (1999) · Nature Cell Biology · doi:10.1038/10042 · Cited by 284
Molecular Gradients of .omega.-Substituted Alkanethiols on Gold: Preparation and Characterization
Liedberg, B., & Tengvall, P. (1995) · Langmuir · doi:10.1021/la00010a037 · Cited by 173
Terrill, R. H., Balss, K. M., Zhang, Y., & Bohn, P. W. (2000) · Journal of the American Chemical Society · doi:10.1021/ja993442n · Cited by 130
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Direct Ink Writing of 3D Functional Materials
Lewis, J. A. (2006) · Advanced Functional Materials · doi:10.1002/adfm.200600434 · Cited by 1,740
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Self-citationBiomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Self-citation
Metadata
- Authors
- Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-10-01
- Volume
- 16
- Issue
- 22
- Pages
- 8311-8316
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1969435013
- Cited by
- 963
- References
- 13
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generation of Solution and Surface Gradients Using Microfluidic Systems. https://app.cochat.ai/papers/10.1021/la000600b
- The paper
- Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000). Generation of Solution and Surface Gradients Using Microfluidic Systems. Langmuir. https://doi.org/10.1021/la000600b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.