Development of a neural network screening aid for diagnosing lower limb peripheral vascular disease from photoelectric plethysmography pulse waveforms
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An artificial neural network (ANN) was trained to classify photoelectric plethysmographic (PPG) pulse waveforms for the diagnosis of lower limb peripheral vascular disease (PVD). PPG pulses from the lower limbs, and pre- and post-exercise Doppler ultrasound ankle to brachial systolic blood pressure ratio measurements were obtained from patients referred to a vascular investigation laboratory. A single PPG pulse from the big toe of each leg was processed and normalized, and used as input data to the ANN. The ANN outputs represented the diagnostic classifications (normal, significant PVD and major PVD) and the ANN was trained with the ankle to brachial pressure indices (ABPI). The ANN structure consisted of an input layer (50 neuron units from the PPG pulse input), a single hidden layer (15 neurons) and an output layer (3 neurons for the PVD diagnoses). The back-propagation learning algorithm was used to train the ANN for 500 epochs with a PPG training set of pulses from 100 legs. Test data for network assessment comprised pulses from a further 50 legs (20 normal and 30 PVD, of which 15 were categorized as having major disease). A network sensitivity of 93% and specificity of 85% was achieved with respect to the Doppler ABPI standard, giving a diagnostic accuracy of 90%. The results of this study indicate that a neural network can be trained to distinguish between PPG pulses from normal and diseased lower limb arteries. The simplicity of PPG measurement and neural network classification holds promise for the screening of lower limb arterial PVD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ankle systolic pressure measurements in arterial disease affecting the lower extremities
Yao, S. T., Hobbs, J. T., & Irivne, W. T. (1969) · Journal of British Surgery · doi:10.1002/bjs.1800560910 · Cited by 542
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“…site, often the ear, finger or toe, where pulses can easily be detected (including Stern (1974), Barnes et al (1977a, 1977b), Sherebrin and Sherebrin (1990), Allen and Murray (1993), Chowienczyk et al (1999), Hahn et al (1999), Bortolotto et al (2000), Foo et al (2006), Millasseau et al (2006)).”
BackgroundMethodInfluentialSelf-citationPhotoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Self-citationRelation between heart rate and pulse transit time during paced respiration
Drinnan, M. J., Allen, J., & Murray, A. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/3/301 · Cited by 167
Self-citation
Metadata
- Authors
- Allen, J., & Murray, A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1993-02-01
- Volume
- 14
- Issue
- 1
- Pages
- 13-22
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2092936182
- Cited by
- 65
- References
- 1
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a neural network screening aid for diagnosing lower limb peripheral vascular disease from photoelectric plethysmography pulse waveforms. https://app.cochat.ai/papers/10.1088/0967-3334/14/1/003
- The paper
- Allen, J., & Murray, A. (1993). Development of a neural network screening aid for diagnosing lower limb peripheral vascular disease from photoelectric plethysmography pulse waveforms. Physiological Measurement. https://doi.org/10.1088/0967-3334/14/1/003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.