The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Half-life of nitric oxide in aqueous solutions with and without haemoglobin
Open accessAbstract
Nitric oxide (NO) has been linked to many regulatory functions in mammalian cells. Studies of NO release are hampered by the short half-life of the molecule. In the blood, NO disappears within seconds because it binds avidly with haemoglobin (Hb). The relationship between Hb concentration and NO disappearance, however, has not been described. In this study we utilized an amperometric NO sensor (WPI, Sarasota, FL) to monitor continuously the disappearance of NO from an aqueous solution when Hb (free or as red blood cells) was added. The calibration and linearity of the NO sensor was checked frequently using a chemical reaction to generate a known concentration of NO. An aliquot of NO solution (prepared from authentic gas) was added to a glass beaker containing 20 ml saline to generate NO concentration of approximately 1200 nM. Under our experimental conditions (PO2 = 40 mmHg), NO concentration fell slowly over 20 min with a half-life of 445 s. However, when haemoglobin was added, NO disappeared rapidly in proportion to Hb concentration. The results suggest that rapid binding of NO to Hb occurs in a 4:1 ratio. The maximum rate constant of NO disappearance due to binding with Hb was 2 x 10(5) M-1 s-1. The 4:1 binding ratio between NO:Hb may be used as a tool to quantitate NO release in some biological assays. The study supports the notion that NO acts as an autocoid because it disappears rapidly in the presence of Hb and is not likely to act as a circulating humoral substance. The NO sensor was useful for monitoring of NO concentration in Hb free solutions, but its response time limits its use in blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ignarro, L. J., Fukuto, J. M., Griscavage, J. M., Rogers, N. E., & Byrns, R. E. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.17.8103 · Cited by 856
Oxidation of nitrogen-oxides by bound dioxygen in hemoproteins
Doyle, M. P., & Hoekstra, J. W. (1981) · Journal of Inorganic Biochemistry · doi:10.1016/s0162-0134(00)80291-3 · Cited by 643
Wink, D. A., Darbyshire, J. F., Nims, R. W., Saavedra, J. E., & Ford, P. C. (1993) · Chemical Research in Toxicology · doi:10.1021/tx00031a003 · Cited by 480
Cited by
Copper complexes of non-steroidal anti-inflammatory drugs: an opportunity yet to be realized
Weder, J. E., Dillon, C. T., Hambley, T. W., Kennedy, B. J., Lay, P. A., Biffin, J. R., Regtop, H. L., & Davies, N. M. (2002) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(02)00086-3 · Cited by 536
Osteocytes: master orchestrators of bone
Schaffler, M. B., Cheung, W.-Y., Majeska, R., & Kennedy, O. (2014) · Calcified Tissue International · doi:10.1007/s00223-013-9790-y · Cited by 514
Diffusion-limited reaction of free nitric oxide with erythrocytes
Liu, X., Miller, M. J. S., Joshi, M. S., Sadowska-Krowicka, H., Clark, D. A., & Lancaster, J. R. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.30.18709 · Cited by 512
Oehmigen, K., Winter, J., Hähnel, M., Wilke, C., Brandenburg, R., Weltmann, K., & von Woedtke, T. (2011) · Plasma Processes and Polymers · doi:10.1002/ppap.201000099 · Cited by 292
Wo, Y., Li, Z., Brisbois, E. J., Colletta, A., Wu, J., Major, T. C., Xi, C., Bartlett, R. H., Matzger, A. J., & Meyerhoff, M. E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b07501 · Cited by 128
Metadata
- Authors
- Hakim, T. S., Sugimori, K., Camporesi, E. M., & Anderson, G.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1996-11-01
- Volume
- 17
- Issue
- 4
- Pages
- 267-277
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2008743229
- Cited by
- 169
- References
- 3
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Half-life of nitric oxide in aqueous solutions with and without haemoglobin. https://app.cochat.ai/papers/10.1088/0967-3334/17/4/004
- The paper
- Hakim, T. S., Sugimori, K., Camporesi, E. M., & Anderson, G. (1996). Half-life of nitric oxide in aqueous solutions with and without haemoglobin. Physiological Measurement. https://doi.org/10.1088/0967-3334/17/4/004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.