CoChat

Half-life of nitric oxide in aqueous solutions with and without haemoglobin

Open access
Hakim, T S, Sugimori, K, Camporesi, E M, Anderson, G · 1996 · Physiological Measurement
Cited by 169

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Nitric oxide (NO) has been linked to many regulatory functions in mammalian cells. Studies of NO release are hampered by the short half-life of the molecule. In the blood, NO disappears within seconds because it binds avidly with haemoglobin (Hb). The relationship between Hb concentration and NO disappearance, however, has not been described. In this study we utilized an amperometric NO sensor (WPI, Sarasota, FL) to monitor continuously the disappearance of NO from an aqueous solution when Hb (free or as red blood cells) was added. The calibration and linearity of the NO sensor was checked frequently using a chemical reaction to generate a known concentration of NO. An aliquot of NO solution (prepared from authentic gas) was added to a glass beaker containing 20 ml saline to generate NO concentration of approximately 1200 nM. Under our experimental conditions (PO2 = 40 mmHg), NO concentration fell slowly over 20 min with a half-life of 445 s. However, when haemoglobin was added, NO disappeared rapidly in proportion to Hb concentration. The results suggest that rapid binding of NO to Hb occurs in a 4:1 ratio. The maximum rate constant of NO disappearance due to binding with Hb was 2 x 10(5) M-1 s-1. The 4:1 binding ratio between NO:Hb may be used as a tool to quantitate NO release in some biological assays. The study supports the notion that NO acts as an autocoid because it disappears rapidly in the presence of Hb and is not likely to act as a circulating humoral substance. The NO sensor was useful for monitoring of NO concentration in Hb free solutions, but its response time limits its use in blood.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/17/4/004

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 169

Metadata

Authors
Hakim, T. S., Sugimori, K., Camporesi, E. M., & Anderson, G.
Venue
Physiological Measurement
Published
1996-11-01
Volume
17
Issue
4
Pages
267-277
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2008743229
Cited by
169
References
24
FWCI
1.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.