CoChat

Reliability of using theD-max method to define physiological responses to incremental exercise testing

Open access
Zhou, Shi, Weston, Shane B · 1997 · Physiological Measurement
Cited by 45

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to examine the reliability of using a mathematical method, D-max, to define blood lactate kinetics in response to an incremental exercise test, and to compare the physiological responses corresponding to the workload at D-max with those at the traditional 4 mmol l-1 lactate threshold and ventilatory thresholds. Ten male endurance trained athletes, with an average (+/- SD) age of 25.6 +/- 8.2 years and maximal oxygen consumption of 64.0 +/- 1.7 ml kg-1 min-1, performed an incremental cycling test on two occasions separated by four weeks. The expired gas was analysed on-line and plasma lactate concentration was analysed for each workload and at exhaustion. The lactate response to exercise was represented by a third-order polynomial regression curve. The D-max was defined as the point on the regression curve that yields the maximal distance to the straight line formed by the two end points of the curve. The results demonstrated a high test-retest reliability (intraclass correlation coefficients 0.77-0.93, p < 0.01) in oxygen consumption, heart rate and exercise intensity at both D-max point and exhaustion. No significant differences were found in the mean values of the variables between the two tests. It is concluded that the D-max appears to be a reliable method for defining the individual physiological responses to exercise tests, with the advantage of objectivity. However, there is no evidence to support the theory that the exercise intensity defined by the D-max method is superior to that defined by other methods to prescribe training intensity or predict aerobic performance for athletes. Further investigations are warranted to examine the validity of using this method in exercise prescription.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/18/2/005

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 45

Metadata

Authors
Zhou, S., & Weston, S. B.
Venue
Physiological Measurement
Published
1997-05-01
Volume
18
Issue
2
Pages
145-154
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2007484265
Cited by
45
References
5
FWCI
0.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of using theD-max method to define physiological responses to incremental exercise testing. https://app.cochat.ai/papers/10.1088/0967-3334/18/2/005
The paper
Zhou, S., & Weston, S. B. (1997). Reliability of using theD-max method to define physiological responses to incremental exercise testing. Physiological Measurement. https://doi.org/10.1088/0967-3334/18/2/005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.