Potential errors in the application of mixture theory to multifrequency bioelectrical impedance analysis
Open accessThe DOI matches its Crossref record.
Abstract
Potential errors in the application of mixture theory to the analysis of multiple-frequency bioelectrical impedance data for the determination of body fluid volumes are assessed. Potential sources of error include: conductive length; tissue fluid resistivity; body density; weight and technical errors of measurement. Inclusion of inaccurate estimates of body density and weight introduce errors of typically but incorrect assumptions regarding conductive length or fluid resistivities may each incur errors of up to 20%. Keywords: mixture theory, errors, bioelectrical impedance analysis, multiple-frequency bioelectrical impedance analysis
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“[37] stated that the differences in biological construction among subjects may limit mixture theory as noted in some studies [38,39].”
ResultBody fluid volume determination via body composition spectroscopy in health and disease
Moissl, U. M., Wabel, P., Chamney, P. W., Bosaeus, I., Levin, N. W., Bosy-Westphal, A., Korth, O., Müller, M. J., Ellegård, L., Malmros, V., et al. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/9/012 · Cited by 608
Dehydration: Physiology, Assessment, and Performance Effects
Cheuvront, S. N., & Kenefick, R. W. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130017 · Cited by 461
“Even the most sophisticated of bioimpedance methods, such as the 0/ ∞ -kHz parallel Cole-Cole and Hanai mixture models (79) contain potential errors (36, 369).”
Bioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Ellis, K. J., Bell, S. J., Chertow, G. M., Chumlea, W. C., Knox, T. A., Kotler, D. P., Lukaski, H. C., & Schoeller, D. A. (1999) · Nutrition · doi:10.1016/s0899-9007(99)00147-1 · Cited by 204
Bioimpedance measurements of human body composition: critical analysis and outlook
Matthie, J. R. (2008) · Expert Review of Medical Devices · doi:10.1586/17434440.5.2.239 · Cited by 199
Assessment of hydration status in a large population
Baron, S., Courbebaisse, M., Lepicard, E. M., & Friedlander, G. (2015) · British Journal of Nutrition · doi:10.1017/s0007114514003213 · Cited by 166
“Ward et al.(85) demonstrated a wide biological variation in a control population.”
Background
Metadata
- Authors
- Ward, L. C., Elia, M., & Cornish, B. H.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1998-02-01
- Volume
- 19
- Issue
- 1
- Pages
- 53-60
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2022301794
- Cited by
- 48
- References
- 0
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.