The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Body fluid volume determination via body composition spectroscopy in health and disease
Open accessAbstract
The assessment of extra-, intracellular and total body water (ECW, ICW, TBW) is important in many clinical situations. Bioimpedance spectroscopy (BIS) has advantages over dilution methods in terms of usability and reproducibility, but a careful analysis reveals systematic deviations in extremes of body composition and morbid states. Recent publications stress the need to set up and validate BIS equations in a wide variety of healthy subjects and patients with fluid imbalance. This paper presents two new equations for determination of ECW and ICW (referred to as body composition spectroscopy, BCS) based on Hanai mixture theory but corrected for body mass index (BMI). The equations were set up by means of cross validation using data of 152 subjects (120 healthy subjects, 32 dialysis patients) from three different centers. Validation was performed against bromide/deuterium dilution (NaBr, D2O) for ECW/TBW and total body potassium (TBK) for ICW. Agreement between BCS and the references (all subjects) was -0.4 +/- 1.4 L (mean +/- SD) for ECW, 0.2 +/- 2.0 L for ICW and -0.2 +/- 2.3 L for TBW. The ECW agreement between three independent reference methods (NaBr versus D2O-TBK) was -0.1 +/- 1.8 L for 74 subjects from two centers. Comparing the new BCS equations with the standard Hanai approach revealed an improvement in SEE for ICW and TBW by 0.6 L (24%) for all subjects, and by 1.2 L (48%) for 24 subjects with extreme BMIs (<20 and >30). BCS may be an appropriate method for body fluid volume determination over a wide range of body compositions in different states of health and disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Self-citationHanai, T. (1960) · Kolloid-Zeitschrift · doi:10.1007/bf01520320 · Cited by 512
THE MEASUREMENT OF TOTAL BODY WATER IN THE HUMAN SUBJECT BY DEUTERIUM OXIDE DILUTION
Schloerb, P. R., Friis-Hansen, B. J., Edelman, I. S., Solomon, A. K., & Moore, F. D. (1950) · Journal of Clinical Investigation · doi:10.1172/jci102366 · Cited by 411
Single- and multifrequency models for bioelectrical impedance analysis of body water compartments
Gudivaka, R., Schoeller, D. A., Kushner, R. F., & Bolt, M. J. G. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.3.1087 · Cited by 261
Bruce, A., Andersson, M., Arvidsson, B., & Isaksson, B. (1980) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518009101869 · Cited by 187
Wong, W. W., Cochran, W., Klish, W. J., Smith, E., Lee, L. S., & Klein, P. (1988) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.1 · Cited by 156
Adipose tissue density, estimated adipose lipid fraction and whole body adiposity in male cadavers.
Martin, A. D., Daniel, M., Drinkwater, D. T., & Clarys, J. P. (1994) · PubMed · Cited by 144
Cited by
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
Assessment methods in human body composition
Lee, S. Y., & Gallagher, D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e32830b5f23 · Cited by 694
Jaffrin, M. Y., & Morel, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.009 · Cited by 490
Importance of Whole-Body Bioimpedance Spectroscopy for the Management of Fluid Balance
Wabel, P., Chamney, P., Moissl, U., & Jirka, T. (2009) · Blood Purification · doi:10.1159/000167013 · Cited by 375
Self-citationBioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Metadata
- Authors
- Moissl, U. M., Wabel, P., Chamney, P. W., Bosaeus, I., Levin, N. W., Bosy-Westphal, A., Korth, O., Müller, M. J., Ellegård, L., Malmros, V., Kaitwatcharachai, C., Kuhlmann, M. K., Zhu, F., & Fuller, N. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2006-07-25
- Volume
- 27
- Issue
- 9
- Pages
- 921-933
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1966195317
- Cited by
- 608
- References
- 21
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Body fluid volume determination via body composition spectroscopy in health and disease. https://app.cochat.ai/papers/10.1088/0967-3334/27/9/012
- The paper
- Moissl, U. M., Wabel, P., Chamney, P. W., Bosaeus, I., Levin, N. W., Bosy-Westphal, A., Korth, O., Müller, M. J., Ellegård, L., Malmros, V., Kaitwatcharachai, C., Kuhlmann, M. K., Zhu, F., & Fuller, N. J. (2006). Body fluid volume determination via body composition spectroscopy in health and disease. Physiological Measurement. https://doi.org/10.1088/0967-3334/27/9/012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.