Optimizing electrode sites for segmental bioimpedance measurements
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Recent advances in the application of bioelectrical impedance analysis (BIA) have indicated that a more accurate approach to the estimation of total body water is to consider the impedance of the various body segments rather than simply that of the whole body. The segmental approach necessitates defining and locating the physical demarcation between both the trunk and leg and the trunk and arm. Despite the use of anatomical markers, these points of demarcation are difficult to locate with precision between subjects. There are also technical problems associated with the regional dispersion of the current distribution from one segment (cylinder) to another of different cross-sectional area. The concept of equipotentials in line with the proximal aspects of the upper (and lower) limbs along the contralateral limbs was investigated and, in particular, the utility of this concept in the measurement of segmental bioimpedance. The variation of measured segmental impedance using electrode sites along these equipotentials was less than 2.0% for all of the commonly used impedance parameters. This variation is approximately equal to that expected from biological variation over the measurement time. It is recommended that the electrode sites, for the measurement of segmental bioelectrical impedance in humans, described herein are adopted in accordance with the proposals of the NIH Technology Assessment Conference Statement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152 · cited 3×
“(1) However the measured impedance is frequency dependent and the nature of this dependence is discussed in depth by such authors as Cole and Cole (1941), Schanne and Ruiz P-Ceretti (1978) and Ackmann and Seitz (1984).”
BackgroundInfluentialAssessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Why bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361
Cited by
New bioimpedance analysis system: improved phenotyping with whole-body analysis
Pietrobelli, A., Rubiano, F., St-Onge, M.-P., & Heymsfield, S. B. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601993 · Cited by 379
Campa, F., Toselli, S., Mazzilli, M., Gobbo, L. A., & Coratella, G. (2021) · Nutrients · doi:10.3390/nu13051620 · Cited by 315
Lukaski, H. C. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.149 · Cited by 303
Bosy-Westphal, A., Jensen, B., Braun, W., Pourhassan, M., Gallagher, D., & Müller, M. J. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2017.27 · Cited by 231
Shafer, K. J., Siders, W. A., Johnson, L. K., & Lukaski, H. C. (2009) · Nutrition · doi:10.1016/j.nut.2008.07.004 · Cited by 223
Metadata
- Authors
- Cornish, B. H., Jacobs, A., Thomas, B. J., & Ward, L. C.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 20
- Issue
- 3
- Pages
- 241-250
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2157682878
- Cited by
- 142
- References
- 3
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimizing electrode sites for segmental bioimpedance measurements. https://app.cochat.ai/papers/10.1088/0967-3334/20/3/302
- The paper
- Cornish, B. H., Jacobs, A., Thomas, B. J., & Ward, L. C. (1999). Optimizing electrode sites for segmental bioimpedance measurements. Physiological Measurement. https://doi.org/10.1088/0967-3334/20/3/302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.