The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Open accessAbstract
Alternatives to conventional wet electrode types are keenly sought for biomedical use and physiological research, especially when prolonged recording of biosignals is demanded. This paper describes a quantitative comparison of three types of bioelectrode (wet, dry and insulating) based on tests involving electrode impedance, static interference and motion artefact induced by various means. Data were collected simultaneously, and in the same physical environment for all electrode types. Results indicate that in many situations the performance of dry and insulating electrodes compares favourably with wet electrodes. The influence of non-stationary electric fields on shielded dry and insulating electrode types was compared to wet types. It was observed that interference experienced by dry and insulating electrode types was 40 dB and 34 dB less than that experienced by wet electrode types. Similarly, the effect of motion artefact on dry and insulating electrodes was compared to wet types. Artefact levels for dry and insulating electrodes were significantly higher than those for wet types at the beginning of trials conducted. By the end of the trial periods artefact levels for dry and insulating types were lower than wet electrodes by an average of 8.2 dB and 6.8 dB respectively. The reservations expressed in other studies regarding the viability of dry and insulating electrodes for reliable sensing of biosignals are not supported by the work described here.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Applied Biomedical Instrumentation.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-83-6-924_2 · Cited by 561
Reducing Motion Artifacts and Interference in Biopotential Recording
Webster, J. G. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325244 · Cited by 181
A dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 176
Capacitive Electrocardiographic and Bioelectric Electrodes
López, A., & Richardson, P. C. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502613 · Cited by 147
The origin of skin-stretch-caused motion artifacts under electrodes
de Talhouet, H., & Webster, J. G. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/2/003 · Cited by 142
Onaral, B., & Schwan, H. P. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442796 · Cited by 131
Electrocardiogram Recording with Pasteless Electrodes
Bergey, G. E., Squires, R. D., & Sipple, W. C. (1971) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1971.4502833 · Cited by 108
Non-linear electrical properties of skin in the low frequency range
Yamamoto, T., & Yamamoto, Y. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442549 · Cited by 95
Noise characteristics of stainless-steel surface electrodes
Godin, D. T., Parker, P. A., & Scott, R. N. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446089 · Cited by 69
Clinical application of an active electrode using an operational amplifier
Nishimura, S., Tomita, Y., & Horiuchi, T. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.161342 · Cited by 69
Contact dermatitis from propylene glycol in ECG electrode gel
Uter, W. J. C., & Schwanitz, H. J. (1996) · Contact Dermatitis · doi:10.1111/j.1600-0536.1996.tb02190.x · Cited by 61
Microelectronic skin electrode
Padmadinata, F. Z., Veerhoek, J. J., van Dijk, G. J. A., et al. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80257-z · Cited by 42
Pasteless electrode for clinical use
Luca, C. J. D., Fever, R. S. L., & Stulen, F. B. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443828 · Cited by 37
Anodic Insulated Tantalum Oxide Electrocardiograph Electrodes
Lagow, C. H., Sladek, K. J., & Richardson, P. C. (1971) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1971.4502820 · Cited by 36
An active, microfabricated, scalp electrode array for EEG recording
Alizadeh-Taheri, B., Smith, R. L., & Knight, R. T. (1996) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80023-4 · Cited by 36
Real time impedance plots with arbitrary frequency components
Searle, A., & Kirkup, L. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/1/008 · Cited by 33
Self-citationCapacitive Type of Biomedical Electrode
Potter, A. G., & Menke, L. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502765 · Cited by 31
Some new electrode techniques for long-term physiologic monitoring.
Pc, R., Coombs, F. K., & Adams, R. M. (1968) · PubMed · Cited by 31
Time and frequency dependence of disposable ECG electrode-skin impedance.
Olson, W. H., Schmincke, D. R., & Henley, B. L. (1980) · PubMed · Cited by 24
A two stage mass spectrometer for nuclear physics applications
Wilson, H., Munro, R., Hardy, R. W. D., & Daly, N. R. (1961) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(61)90215-4 · Cited by 14
Cited by
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Multifunctional Epidermal Electronics Printed Directly Onto the Skin
Yeo, W., Kim, Y., Lee, J., Ameen, A., Shi, L., Li, M., Wang, S., Ma, R., Jin, S. H., Kang, Z., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204426 · Cited by 828
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Metadata
- Authors
- Searle, A., & Kirkup, L.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2000-05-01
- Volume
- 21
- Issue
- 2
- Pages
- 271-283
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2055063605
- Cited by
- 725
- References
- 20
- FWCI
- 0.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.