Measurement of high resolution ECG QT interval during controlled euglycaemia and hypoglycaemia
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
During hypoglycaemia, typically there is a change in the surface ECG characterized by a flattened and prolonged T wave, often accompanied by a fused U wave. The QT interval is a useful parameter for quantifying the ECG morphology. However, reliable measurement of QT is not straightforward, particularly for hypoglycaemic ECG morphology. The objective of this study was to compare the ability of two methods of QT measurement to distinguish between ECGs recorded during euglycaemia and hypoglycaemia. The first method involves manually setting the intersection of the isoelectric line and the T wave or, where this is not possible, the nadir between the T and U wave. The second method is semi-automatic and fits a tangent to the point of maximum gradient on the downward slope of the T wave. Two independent observers used both methods to measure the QT for high resolution ECG data recorded during a study of 17 non-diabetic subjects undergoing controlled euglycaemia and hypoglycaemia. Using the mean results of the two observers, the mean +/- SD increase in heart rate corrected QT, QTc, for ECGs recorded during euglycaemia and hypoglycaemia was 32 +/- 25 ms for the non-tangent method and 60 +/- 24 ms for the tangent method. Therefore, the tangent method provides greater distinction between ECGs recorded during euglycaemia and hypoglycaemia than the non-tangent method. A potential clinical application could be the non-invasive detection of impending hypoglycaemia at night, which would be of significant benefit to adults and young children with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Diurnal pattern of QTc interval: How long is prolonged?
Molnar, J., Zhang, F., Weiss, J., Ehlert, F. A., & Rosenthal, J. E. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00426-2 · Cited by 312
Liu, D., Moberg, E., Kollind, M., Lins, P. E., Adamson, U., & Macdonald, I. A. (1992) · Diabetologia · doi:10.1007/bf00400932 · Cited by 162
Cited by
Mechanisms of abnormal cardiac repolarization during insulin-induced hypoglycemia
Robinson, R. T. C. E., Harris, N. D., Ireland, R. H., Lee, S., Newman, C., & Heller, S. R. (2003) · Diabetes · doi:10.2337/diabetes.52.6.1469 · Cited by 264
Self-citationRobinson, R. T. C. E., Harris, N. D., Ireland, R. H., Macdonald, I. A., & Heller, S. R. (2004) · Diabetologia · doi:10.1007/s00125-003-1292-4 · Cited by 137
Self-citationElectrocardiographic Alterations during Hyperinsulinemic Hypoglycemia in Healthy Subjects
Laitinen, T., Lyyra‐Laitinen, T., Huopio, H., Vauhkonen, I., Halonen, T., Hartikainen, J., Niskanen, L., & Laakso, M. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00208.x · Cited by 107
Murphy, N. P., Ford-Adams, M. E., Ong, K. K., Harris, N. D., Keane, S. M., Davies, C., Ireland, R. H., MacDonald, I. A., Knight, E. J., Edge, J. A., et al. (2004) · Diabetologia · doi:10.1007/s00125-004-1552-y · Cited by 88
Self-citationNon-invasive hypoglycemia monitoring system using extreme learning machine for Type 1 diabetes
Ling, S. H., San, P. P., & Nguyen, H. T. (2016) · ISA Transactions · doi:10.1016/j.isatra.2016.05.008 · Cited by 62
“10 Healthy [24] 400 20 450 70 17 Healthy [25] 406 16 480 90 8 T1DM [26] 407 16 448 57 17 Healthy [27] 399 7 459 67 16 T1DM and 8 Healthy [28] 410 10 419 13 18 Healthy [29] 408 9 429 30”
Metadata
- Authors
- Ireland, R. H., Robinson, R. T. C. E., Heller, S. R., Marques, J. L. B., & Harris, N. D.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2000-05-01
- Volume
- 21
- Issue
- 2
- Pages
- 295-303
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2024337285
- Cited by
- 38
- References
- 3
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.