Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Respiratory monitoring using an air-mattress system

Chow, Patrick, Nagendra, Gangadharan, Abisheganaden, John, Wang, Y T · 2000 · Physiological Measurement

Abstract

This paper describes a non-invasive respiratory monitoring system using an air mattress. The air-mattress system features multiple air compartments to monitor movements of the thorax and the abdomen separately. To evaluate the performance of the air-mattress system, four subjects were selected for the study and their separate ribcage and abdominal movements were monitored simultaneously by respiratory inductive phlethysmography belts and the air-mattress system. The sensitivity and accuracy indices of the air-mattress system for the detection of hypopnoeas scored remarkably well (above 90%). In addition, it was noted that the mean error in the measurement of the respiratory rate between the two systems was very small. This paper shows that the air-mattress system can be a reliable non-invasive respiratory monitoring system to detect simple abnormalities in breathing, such as respiration rate and hypopnoeas.

Overview

Integrity signals

Registry

Crossref · 10.1088/0967-3334/21/3/301

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 9 references

Research works printed but not linked: 2

  1. Alihanka J, 1981, Am. J. Physiol., 240, R384
  2. Staats B A, 1984, Am. Rev. Resp. Dis., 130, 59

Cited by

See all 45

Metadata

Authors
Chow, P., Nagendra, G., Abisheganaden, J., & Wang, Y. T.
Affiliations
  • Singapore Polytechnic (SG)
  • Tan Tock Seng Hospital (SG)
Venue
Physiological Measurement
Published
2000-08-01
Volume
21
Issue
3
Pages
345-354
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2083278499
Cited by
45
References
9
Citations by year
2024: 1 · 2023: 3 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 1
FWCI
0.69
Type
journal article
Language
en
Open access
closed
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
respiratory monitoring, air mattress, non-invasive monitoring, thoracic movement, abdominal movement, respiratory rate measurement, respiratory inductance plethysmography, breathing abnormalities
MeSH terms
Abdomen, Adult, Air, Anthropometry, Beds, Humans, Male, Middle Aged, Monitoring, Physiologic, Movement, Plethysmography, Sensitivity and Specificity, Sleep, Thorax, Respiratory Mechanics, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Respiratory monitoring using an air-mattress system. https://app.cochat.ai/papers/10.1088/0967-3334/21/3/301
The paper
Chow, P., Nagendra, G., Abisheganaden, J., & Wang, Y. T. (2000). Respiratory monitoring using an air-mattress system. Physiological Measurement. https://doi.org/10.1088/0967-3334/21/3/301

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.