A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration
The DOI matches its Crossref record.
Abstract
The principle of the static charge-sensitive-bed (SCSB) method is described. The method is simple and inexpensive. From the SCSB recording the ballistocardiogram (BCG) and respiratory movement can be simultaneously recorded by selective filtering of the original signal. The SCSB recording thus enables continuous long-term monitoring of the BCG, heart rate, respiratory rate, respiratory amplitude, and body movements. There are no electrodes or cables connected to the subject. The SCSB-BCG signal was studied by comparing the SCSB method with the conventional ultralow-frequency (ULF) acceleration BCG. The wave forms at rest and the amplitude responses to physical exercise were studied by both methods. Multiple recordings of the BCG, heart rate, respiratory movement, respiratory rate, and body movements after exercise and during sleep using the SCSB method are presented. The SCSB method opens new approaches to long-term studies of the regulation of myocardial performance, heart rate, and respiration. Applications of the SCSB method for clinical sleep studies, patient monitoring and cardiovascular screening examinations are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644
Noninvasive Monitoring of Vital Signs Based on Highly Sensitive Fiber Optic Mattress
Wang, S., Ni, X., Li, L., Wang, J., Liu, Q., Yan, Z., Zhang, L., & Sun, Q. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2974313 · Cited by 71
Respiratory monitoring using an air-mattress system
Chow, P., Nagendra, G., Abisheganaden, J., & Wang, Y. T. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/3/301 · Cited by 45
A nurse‐managed weight reduction programme for obstructive sleep apnoea syndrome
Lojander, Mustajoki, Rönkä, Mecklin, & Maasilta (1998) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.1998.00387.x · Cited by 41
Metadata
- Authors
- Alihanka, J., Vaahtoranta, K., & Saarikivi, I.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 1981-05-01
- Volume
- 240
- Issue
- 5
- Pages
- R384-R392
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2342847974
- Cited by
- 270
- References
- 0
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration. https://app.cochat.ai/papers/10.1152/ajpregu.1981.240.5.r384
- The paper
- Alihanka, J., Vaahtoranta, K., & Saarikivi, I. (1981). A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration. American Journal of Physiology-Regulatory, Integrative and Comparative Physiology. https://doi.org/10.1152/ajpregu.1981.240.5.r384
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.