The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Open accessAbstract
We aimed to validate a new method for measuring arterial pulsewave transit time and pulsewave velocity (a measure of arterial elasticity), based on the principle of photoplethysmography (PPG), and to compare transcutaneous values with those obtained by intra-arterial measurements. Three validation experiments are described. (a) PPG pulse wave delay times (defined as the time interval between the ECG R wave and the foot of the arterial pulse wave measured at the wrist or ankle) were compared to values obtained simultaneously from an established methodology (Doppler ultrasound). (b) Aortic pulsewave delay times in 17 subjects obtained non-invasively by the PPG method were compared with those obtained from the intra-arterial pressure wave. (c) Repeatability measurements of PWV on the same subjects were carried out over two timescales (minutes and hours) in the arm, the leg and the trunk. The Doppler and PPG delay times correlated well, as did intra-arterial and transcutaneous values. Repeatability at short timescales was good (coefficients of variation (CV) < 6% for all measurement sites) and, at the longer timescale, was satisfactory (CVs in the aorta, the arm and leg were 6.3, 13.1 and 16.0, respectively). The PWV values agreed well with others in the literature. We conclude that the PPG technique provides a complement to existing methods for the non-invasive measurement of arterial compliance. Its simplicity and ease of use make it suitable for large-scale epidemiological studies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“advances in sensor technology for arterial pulse waveform and speed detection have paved the way for the potential development of devices for cuffless measurement of BP, in the perspective of continuous, beat-by-beat monitoring [103–106]”
In the citing paper
“some of such devices have been validated according to ad hoc draft protocols whereas others according to standard protocols [107,108], thus resulting in heterogenous and difficult to interpret evidence on their accuracy”
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Avolio, A. P., Chen, S. G., Wang, R. P., Zhang, C. L., Li, M., & OʼRourke, M. F. (1983) · Circulation · doi:10.1161/01.cir.68.1.50 · Cited by 965
The Fluid Mechanics of Large Blood Vessels
Pedley, T. J., & Fung, Y. C. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138235 · Cited by 916
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Avolio, A. P., Deng, F. Q., Li, W. Q., Luo, Y., Huang, Z., Xing, L. F., & O’Rourke, M. F. (1985) · Circulation · doi:10.1161/01.cir.71.2.202 · Cited by 838
Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension.
O'Rourke, M. (1990) · Hypertension · doi:10.1161/01.hyp.15.4.339 · Cited by 621
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B., Reuderink, P., & Murgo, J. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 499
Growth in utero, adult blood pressure, and arterial compliance.
Martyn, C. N., Barker, D. J. P., Jespersen, S., Greenwald, S. E., Osmond, C., & Berry, C. L. (1995) · Heart · doi:10.1136/hrt.73.2.116 · Cited by 362
Self-citationDetermination of pulse wave velocities with computerized algorithms
Chiu, Y. C., Arand, P. W., Shroff, S. G., Feldman, T. E., & Carroll, J. D. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90153-9 · Cited by 313
Tardy, Y., Meister, J. ‐., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 268
Research works printed but not linked: 4
- Greenwald S E, 1991, Med. Razgl., 30, 143
- Lehmann E D, 1999, Pathol. Biol. (Paris), 47, 716
- Plunkett B T, 1996, Zeit. Kardiol., 85, 136
- Sapoznikov D, 1974, Eur. J. Cardiol., 1, 447
Cited by
Sorted by citations
Items 101–164 of 164
Physiological origin of camera-based PPG imaging
Kamshilin, A. A., & Mamontov, O. V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822281-2.00010-x · Cited by 8
Zhao, R., Du, L., Zhao, Z., Chen, X., Sun, J., Man, Z., Cao, B., & Fang, Z. (2021) · Frontiers in Digital Health · doi:10.3389/fdgth.2021.747460 · Cited by 11
Pulse wave analysis as an experimental tool to clinical application: Past and present (Review)
Bhagat, A., Kapoor, N., & Bhagat, H. (2011) · Acta Physiologica Hungarica · doi:10.1556/aphysiol.98.2011.4.2 · Cited by 8
Imms, R., Hu, S., Azorin-Peris, V., Trico, M., & Summers, R. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2044318 · Cited by 8
Freeman, R., & Carson, P. (2003) · International Journal of Paediatric Dentistry · doi:10.1046/j.1365-263x.2003.00480.x · Cited by 8
Photoplethysmography technology
Budidha, K., & Kyriacou, P. A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00002-5 · Cited by 7
Antidepressants in social anxiety disorder
Nardi, A. E. (2001) · Arquivos de Neuro-Psiquiatria · doi:10.1590/s0004-282x2001000400032 · Cited by 8
Kumar, S., Tayade, A., Shrivastava, A., & Ravi, B. (2025) · Scientific Reports · doi:10.1038/s41598-025-98488-w · Cited by 6
Huang, L., Geng, X., Xu, H., Zhang, Y., Li, Z., Zhang, J., & Zhang, H. (2021) · Electronics · doi:10.3390/electronics10222867 · Cited by 6
Prabhakar, S. K., & Rajaguru, H. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-4220-1_15 · Cited by 6
Tattoo Assisted Optical Sensor System for Multimodal Discrete Physiological Sensing
Wu, Z., El‐Barbary, A., Lafleur, D., Zhuo, S., Williams, C. M., & Ameri, S. K. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202404933 · Cited by 5
Zou, H., Zhang, Y., Zhang, J., Chen, C., Geng, X., Zhang, S., & Zhang, H. (2020) · Algorithms · doi:10.3390/a13110297 · Cited by 5
Lingqin, 孔. K., Yuejin, 赵. Z., Dong, L., Ming, 刘. L., Ge, 徐. X., Mei, 惠. H., & Xuhong, 褚. C. (2023) · Acta Optica Sinica · doi:10.3788/aos230755 · Cited by 5
Electrocardiogram R-wave is an Unreliable Indicator of Pulse Wave Initialization
Balmer, J., Pretty, C. G., Kamoi, S., Davidson, S. M., Pironet, A., Desaive, T., Shaw, G. M., & Chase, J. G. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.254 · Cited by 5
Photoplethysmographic assessment of arterial stiffness and endothelial function
Zheng, D., Yao, Y., Morrison, I., & Greenwald, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00007-4 · Cited by 7
Self-citationDjupedal, H., Nøstdahl, T., Hisdal, J., Landsverk, S. A., & Høiseth, L. O. (2022) · Physiological Reports · doi:10.14814/phy2.15355 · Cited by 4
Low-Cost Mobile Device for Screening of Atherosclerosis and Coronary Arterial Disease
Pignatelli, N., Ma, B., Sengputa, S., Sengupta, P. P., Mungulmare, K., & Fletcher, R. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513612 · Cited by 5
Hoonjan, B., Dulai, R. S., Ahmed, Z., Lucey, A. J., Twycross-Lewis, R., Morrissey, D., & Greenwald, S. E. (2013) · Artery Research · doi:10.1016/j.artres.2013.08.002 · Cited by 5
Self-citationMethodological Advances on Pulse Measurement through Functional Imaging
Bourlai, T., Buddharaju, P., Pavlidis, I. T., & Bass, B. L. (2009) · Springer eBooks · doi:10.1007/978-1-4419-1123-0_6 · Cited by 4
The Effect of Local Cold Exposure on Pulse Transit Time
Zhang, X., & Zhang, Y. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1617239 · Cited by 4
Pulse wave transit time measured by imaging photoplethysmography in upper extremities
Volynsky, M. A., Mamontov, O. V., Sidorov, I. S., & Kamshilin, A. A. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/737/1/012053 · Cited by 4
Reliability of Hemodynamic Parameters Measured by a Novel Photoplethysmography Device
Grabovskis, A., Kviesis-Kipge, E., Marcinkevičs, Z., Lusa, V., Volceka, K., & Grēve, M. (2011) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-21683-1_50 · Cited by 4
Pulse transit time measurement method with artifact tolerance for home healthcare
Shiraishi, N., & Sankai, Y. (2013) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2013.6618036 · Cited by 3
Correlation of self-reported physical activity with pulse wave velocity in male adolescents
Miura, H., Maruoka, S., & Sugino, M. (2012) · The Journal of Physical Fitness and Sports Medicine · doi:10.7600/jpfsm.1.191 · Cited by 3
Geng, X., Liu, S., Zhang, Y., Zhang, S., Hou, J., Zhang, J., Asif, M., & Zhang, H. (2020) · Journal of Sensors · doi:10.1155/2020/1953506 · Cited by 3
Benchemoul, M., Mateo, T., Savéry, D., Géhin, C., Massot, B., Ferin, G., Vince, P., & Flesch, M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629889 · Cited by 3
Margain, T. C., Powell, E., Clark, A. L., & Bush, A. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1481836 · Cited by 2
Nuevos modelos conceptual y matemático para el contorno de la onda de volumen de pulso arterial
Simon, A., Rodríguez, J. E. F.-B., & Allen, J. (2011) · Revista cubana de investigaciones biomédicas · Cited by 2
Hoonjan, B., Dulai, R. S., Ahmed, M., Lucey, A. J., Morrissey, D., Twycross-Lewis, R., & Greenwald, S. (2011) · British Journal of Sports Medicine · doi:10.1136/bjsports-2011-090606.24 · Cited by 2
Self-citationChou, H., Lin, K.-J., Fang, Y.-X., & Liou, J.-F. (2015) · Technology and Health Care · doi:10.3233/thc-151055 · Cited by 2
Qawqzeh, Y., Reaz, M. B. I., Maskon, O., Chellappan, K., Islam, M. T., & Ali, M. A. M. (2011) · International Conference on Signal Processing · Cited by 2
Zhou, K., Yin, Z., Guo, F., & Li, J. (2021) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/1386207324666210705113121 · Cited by 2
Analysis and research on the change of characteristic parameters with age based on PPG signal
Tao, H., Zhang, J., & Jiu-li, C. U. I. (2022) · Asia Pacific Conference on Optics Manufacture and International Forum of Young Scientists on Advanced Optical Manufacturing (APCOM and YSAOM) · doi:10.1117/12.2618001 · Cited by 2
Assessment of conduit artery vasomotion using photoplethysmography
Kanders, K., Grabovskis, A., Marcinkevičs, Z., & Aivars, J. I. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2044705 · Cited by 2
A Study of the Dynamic Relation between Physiological Changes and Spontaneous Expressions
Yang, F., Hu, S., Li, B., Dwyer, V. M., Hassan, H., Wei, D., & Shi, P. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-07122-x · Cited by 2
A NEW LOW-COMPLEXITY ALGORITHM FOR THE PULSE TRANSIT TIME EVALUATION
Lilia, R., & Omari, T. (2023) · Bioscience & Engineering An International Journal · doi:10.5121/bioej.2023.10202 · Cited by 1
Huang, L., Zhai, X., Tian, P., Dai, Z., Wang, Y., Zhang, H., & Zhang, J. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3559555 · Cited by 1
Lin, H.-D., Lee, Y.-S., Su, Y.-J., & Chuang, B.-N. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090039 · Cited by 1
Yang, F., Hu, S., Ma, X., Hassan, H., & Wei, D. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2077120 · Cited by 1
Evaluation of ANN and SVM for the classification and prediction of patients with diabetic neuropathy
Rubio, T. G., & Castillo, A. S. (2012) · XVIII Congreso Argentino de Ciencias de la Computación · Cited by 1
Smart photoplethysmographic sensor for pulse wave registration at different vascular depths
Leier, M., Pilt, K., Karai, D., & Jervan, G. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318741 · Cited by 2
Pulse transit time as surrogate measure of blood pressure in children
Foo, J. Y. A., Wilson, S. J., Williams, G. R., Harris, M., & Cooper, D. M. (2005) · International Conference on Biomedical Engineering · Cited by 1
A Correlation Study on the Features of Photoplethysmographic Signals
Gu, Y., & Zhang, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmd.2004.1689574
Long-term cardiovascular follow-up after preterm birth
Bonamy, A. E. (2008) · Figshare
Vascular and Platelet Function in Insulin Resistance
Tamminen, M. (2004) · Työväentutkimus Vuosikirja
Grabovskis, A., Marcinkevičs, Z., Rubīns, U., & Aivars, J. I. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.3.035001
Measurement of the arterial pulse wave with biomagnetic technique
Córdova–Fraga, T., Huerta, C., Sosa, M., Huerta, R., Vargas, M., Hernández, E., & Bernal, J. J. (2007) · International Congress Series · doi:10.1016/j.ics.2006.12.074
Roytvarf, A. A., & Shusterman, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912668
Segers, P., Boutouyrie, P., & Stergiopulos, N. (2007)
Reinstrup, P., Ryding, E., Ohlsson, T., Sandell, A., Erlandsson, K., Ljunggren, K., Salford, L. G., Strand, S., & Uski, T. K. (2008)
Teixeira, L., Duarte, D., & Saraiva, R. Â. (2009)
CARDIOVASCULAR FOLLOW-UP AFTER PRETERM BIRTH
Bonamy, A. E., Anna-karin, A., Bonamy, E., & Bonamy, A.-K. E. (2016)
Development of Easy Measurement Device for Screening of Arterial Sclerosis of Lower Limbs
Shiraishi, N., & Sankai, Y. (2013) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.79.2694
Towards Pulse Wave Velocity Estimation Using Specific ECG and PPG Algorithms
Borik, Š., & Babušiak, B. (2016) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-39796-2_23
The effects of physical activity and yoga on Carotid artery stiffness
Duren, C. M. (2006)
Går det att mäta blodtryck med fotopletysmografi och bioakustisk sensor i kombination
Öhman, F. (2004) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Autonomic Nerve Activation Observed for Hemodialysis Patients While Squeezing a Soft Ball
Liou, J.-C., Peng, C., Basset, P., & Chen, Z.-X. (2020) · Sustainability · doi:10.3390/su12229646
A NEW ALGORITHM FOR MEASURING PULSE TRANSIT TIME FROM ECG AND PPG SIGNALS
Lilia, R., & Taha, O. (2023) · International journal of Biomedical Engineering and Science · doi:10.5121/ijbes.2023.10101
uFISIO: Evaluation of a Standalone Device for Arterial Stiffness Assessment and Wave Analysis
Travado, H., Luca, M. D., Miranda, M. C., Ramirez, C. R., Armentano, R. L., & Cymberknop, L. J. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-61960-1_21
Lifestyle and arterial stiffness in young adults: A life course approach
van de Laar, R. J. J. (2013) · doi:10.26481/dis.20130307rl
Metadata
- Authors
- Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E.
- Affiliations
- St Bartholomew's Hospital (GB)
- Southampton General Hospital (GB)
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2002-07-15
- Volume
- 23
- Issue
- 3
- Pages
- 581-596
- ISSN
- 0967-3334 (ISSN-L)
- OpenAlex
- W2006542548
- Cited by
- 164
- References
- 41
- Citations by year
- 2025: 5 · 2024: 3 · 2023: 6 · 2022: 4 · 2021: 12 · 2020: 6 · 2019: 3 · 2018: 7 · 2017: 8 · 2016: 4 · 2015: 9 · 2014: 2 · 2013: 6 · 2012: 11
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- ePrints Soton (University of Southampton) (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- pulse wave velocity, photoplethysmography, arterial compliance, pulse transit time, aortic pulse wave, Doppler ultrasound comparison, repeatability
- MeSH terms
- Ankle, Catheterization, Peripheral, Circadian Rhythm, Compliance, Femoral Artery, Heart Rate, Humans, Pulsatile Flow, Pulse, Wrist, Reproducibility of Results, Photoplethysmography, Ultrasonography, Doppler
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review