Cited by 873Cardiovascular Health and Disease PreventionNon-Invasive Vital Sign MonitoringHemodynamic Monitoring and Therapy

An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man

KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., KELLY, R. P.·1993·European Heart Journal

Abstract

Amplification of the pressure pulse between central and peripheral arteries renders pressure values in the upper limb an inaccurate measure of ascending aortic (AA) pressure. Accuracy could be improved by allowance for such amplification. Transfer functions (TF) for pressures between AA and brachial artery (BA):(BATF) and between AA and radial artery (RA):(RATF) were derived from high-fidelity pressure recordings obtained at cardiac catheterization in 14 patients under control conditions, and after sublingual nitroglycerine 0.3 mg. There was no significant difference in BATF under control conditions and with nitroglycerine; hence results were pooled. Control and nitroglycerine results were also pooled to obtain a single RATF. BATF and RATF moduli peaked at 5 Hz and 4 Hz, reaching 2.5 and 2.8 times the value at zero frequency respectively. Frequency-dependent changes in modulus and phase of BATF and RATF were attributable to wave travel and reflection in the upper limb. BATF and RATF were compared to published transfer functions and those derived from analysis of aortic and brachial or radial pressure waves in previous publications. Results were similar. Our BATF and RATF were used to synthesize AA pressure waves from published peripheral pulses. Correspondence was close, especially for systolic pressure which differed by 2.4 +/- 1.0 (mean +/- SEM) mmHg, whereas recorded systolic pressure differed by 20.4 +/- 2.6 (mean +/- SEM) mmHg between central and peripheral sites. Results indicate that in adult humans a single generalized TF can be used with acceptable accuracy to determine central from peripheral pressure under different conditions.(ABSTRACT TRUNCATED AT 250 WORDS)

Integrity signals

Registry

Crossref · 10.1093/eurheartj/14.2.160

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • When a validated integral transfer function is applied, the aortic pressure waveform can be derived from radial artery pressure waveform.

    “Radial artery pressure waveform is recorded noninvasively by applanation tonometry, 15 and when a validated integral transfer function is applied, 16 the aortic pressure waveform can be derived.”
  • Augmentation index was measured using a validated, commercially available system (SphygmoCor).

    “The augmentation index was measured by using a validated, commercially available system (SphygmoCor; AtCor Medical, Sydney, Australia) that employs the principle of applanation tonometry and appropriate acquisition and analysis software for noninvasive recording and analysis of the arterial pulse.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P.
Affiliations
  • UNSW Sydney (AU)
  • St Vincent's Hospital Sydney (AU)
Venue
European Heart Journal
Published
1993-02-02
Volume
14
Issue
2
Pages
160-167
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2067833505
Cited by
873
References
24
Citations by year
2026: 5 · 2025: 6 · 2024: 13 · 2023: 17 · 2022: 25 · 2021: 26 · 2020: 22 · 2019: 20 · 2018: 25 · 2017: 28 · 2016: 34 · 2015: 30 · 2014: 50 · 2013: 43 · 2012: 48
FWCI
5.61
Type
journal article
Language
en
Open access
closed
Locations
  • European Heart Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
central blood pressure, peripheral arterial pressure, transfer function, brachial artery, radial artery, wave reflection, systolic blood pressure, arterial blood pressure measurement
MeSH terms
Adult, Aged, Aorta, Blood Pressure, Brachial Artery, Female, Humans, Male, Manometry, Middle Aged, Models, Biological, Radial Artery

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review