CoChat

Comparison of caffeine-induced changes in cerebral blood flow and middle cerebral artery blood velocity shows that caffeine reduces middle cerebral artery diameter

Open access
Lunt, M J, Ragab, S, Birch, A A, Schley, D, Jenkinson, D F · 2004 · Physiological Measurement
Cited by 58

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Changes in cerebral blood flow (CBF) can be assessed directly with xenon clearance (XeC) or indirectly by measuring changes in middle cerebral artery blood velocity (Vmca) with transcranial Doppler (TCD). The aim of this study was to compare the changes in CBF and Vmca following caffeine ingestion. Nineteen patients (age 48-86, recovering from an acute stroke) and ten controls (age 52-85) were each studied twice. Bilateral measurements of CBF and Vmca were made before and after ingestion of 250 mg caffeine or matched placebo. The percentage change in CBF and Vmca after caffeine was calculated. Full results (CBF and Vmca) were obtained from 14 patients and 9 controls. There was no significant difference between patients and controls, so results were combined. Caffeine reduced CBF by 22% (95% confidence interval (CI) = 17% to 28%) and reduced Vmca by 13% (95% CI = 10% to 17%). The fall in Vmca was significantly less than that in CBF (p = 0.0016), showing that caffeine reduces mca diameter. Analysis based on Poiseuille flow in the arterioles suggests that caffeine reduced arteriole diameter by 5.9% (95% CI = 4.6% to 7.3%) and mca diameter by 4.3% (95% CI = 2.0% to 6.6%). TCD is being used as an alternative to XeC for assessing the effect of vasoconstrictors and vasodilators on CBF. This study has demonstrated that in mca diameter can be changed by the vasoactive agents, and that changes in Vmca do not necessarily reflect changes in CBF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/25/2/006

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 58

Metadata

Authors
Lunt, M. J., Ragab, S., Birch, A. A., Schley, D., & Jenkinson, D. F.
Venue
Physiological Measurement
Published
2004-02-17
Volume
25
Issue
2
Pages
467-474
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2112185913
Cited by
58
References
2
FWCI
1.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of caffeine-induced changes in cerebral blood flow and middle cerebral artery blood velocity shows that caffeine reduces middle cerebral artery diameter. https://app.cochat.ai/papers/10.1088/0967-3334/25/2/006
The paper
Lunt, M. J., Ragab, S., Birch, A. A., Schley, D., & Jenkinson, D. F. (2004). Comparison of caffeine-induced changes in cerebral blood flow and middle cerebral artery blood velocity shows that caffeine reduces middle cerebral artery diameter. Physiological Measurement. https://doi.org/10.1088/0967-3334/25/2/006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.