CoChat

What is the adequate sampling interval of the ECG signal for heart rate variability analysis in the time domain?

Hejjel, Laszlo, Roth, Elizabeth · 2004 · Physiological Measurement
Cited by 84

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Heart rate variability (HRV) analysis is considered a simple method for investigating neurocardiac regulation. However, measures of HRV may be corrupted by technical artifacts. In order to investigate the consequences of digitization errors on the time domain parameters, HRV measures from model tachograms resampled at different rates were compared. Two 375-element tachograms from human ECG tracings were shifted to a mean of 800 ms and stretched to standard deviations (SD) of 5-120 ms in 5 ms steps. All were resampled at 1-10 ms in 1 ms steps, 10 times repetitively at each interval. The mean, SD, relative accuracy error (RAE) and relative precision error (RPE) were calculated from the mean RR-interval, SD (SDNN), root mean square of successive RR-differences (RMSSD) and the percentage of consecutive RR-interval differences greater than 50 ms (pNN50). The RAE and RPE of the mean heart rate were below 0.1%. In the series with 5 ms SD, the SDNN-RAE exceeded 30% at 10 ms SI, its RPE was lower than 2% all through. Resampling the 15 ms SD tachogram at 1, 2, 4, or 10 ms resulted in RMSSD-RAE of 0.7%, 2.5%, 7.8% and 45.1%, respectively, while its RPE remained below 5%. The pNN50 shows poor accuracy and precision. An ECG sampling interval of 1 ms is recommended for HRV analysis without interpolation in order to get accurate time domain measures even in seriously reduced-variability samples. However, a lower sampling rate may be satisfactory in cases where higher variability is expected.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/25/6/006

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 84

Metadata

Authors
Hejjel, L., & Roth, E.
Venue
Physiological Measurement
Published
2004-09-15
Volume
25
Issue
6
Pages
1405-1411
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2007946406
Cited by
84
References
2
FWCI
0.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: What is the adequate sampling interval of the ECG signal for heart rate variability analysis in the time domain? https://app.cochat.ai/papers/10.1088/0967-3334/25/6/006
The paper
Hejjel, L., & Roth, E. (2004). What is the adequate sampling interval of the ECG signal for heart rate variability analysis in the time domain? Physiological Measurement. https://doi.org/10.1088/0967-3334/25/6/006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.