The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference
Abstract
Based on EEG data recorded from 11 subjects with eyes open and the left mastoid (M) reference, three data sets were generated by re-referencing to the conventional linked mastoids (L), average (A) and the new 'infinity' (I) reference provided by the reference electrode standardization technique (REST, Yao 2001 Physiol. Meas. 22 693-711). The EEG power in the alpha frequency band with the four different references was calculated and compared with respect to the total energy and spatial amplitude weight centre (AWC) coordinates, to compare the effects of different references on power mapping in the frequency domain. Compared with the I reference, the AWCs of the EEG with the M reference show significant shifts to the right, frontal and superficial positions, the L reference significant shifts to frontal and superficial positions, and the A reference shifts the AWC significantly to a deeper position. Furthermore, the power maps of the M and L references have larger total power than the I reference, while that of the A reference has the smallest total power. These results confirm that different choices of reference electrodes result in systematic changes in the distribution of EEG frequency power, and in order to reduce the effect of such systematic shifts on the explanation of EEG mappings, a common reference is necessary for EEG research. We recommend the I reference for objective use in cross-laboratory studies and clinical practices, as it is far from all the other electrodes and can act as a neutral reference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barry, R. J., Clarke, A. R., & Johnstone, S. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00362-0 · Cited by 819
Theta band power in the human scalp EEG and the encoding of new information
Klimesch, W., Doppelmayr, M., Russegger, H., & Pachinger, T. (1996) · NeuroReport · doi:10.1097/00001756-199605170-00002 · Cited by 422
Cited by
Tenke, C. E., & Kayser, J. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.06.005 · Cited by 273
Graph-based analysis of brain connectivity in schizophrenia
Olejarczyk, E., & Jernajczyk, W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188629 · Cited by 263
Toward an EEG-Based Recognition of Music Liking Using Time-Frequency Analysis
Hadjidimitriou, S. K., & Hadjileontiadis, L. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2217495 · Cited by 260
Arakaki, X., Shoga, M., Li, L., Zouridakis, G., Tran, T., Fonteh, A. N., Dawlaty, J., Goldweber, R., Pogoda, J. M., & Harrington, M. G. (2018) · PLOS ONE · doi:10.1371/journal.pone.0188101 · Cited by 23
Sun, Y., Xu, Y., Lv, J., & Liu, Y. (2022) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2022.108282 · Cited by 11
Metadata
- Authors
- Yao, D., Wang, L., Oostenveld, R., Nielsen, K. D., Arendt-Nielsen, L., & Chen, A. C. N.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2005-02-10
- Volume
- 26
- Issue
- 3
- Pages
- 173-184
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1999127827
- Cited by
- 172
- References
- 2
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference. https://app.cochat.ai/papers/10.1088/0967-3334/26/3/003
- The paper
- Yao, D., Wang, L., Oostenveld, R., Nielsen, K. D., Arendt-Nielsen, L., & Chen, A. C. N. (2005). A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference. Physiological Measurement. https://doi.org/10.1088/0967-3334/26/3/003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.