A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Based on EEG data recorded from 11 subjects with eyes open and the left mastoid (M) reference, three data sets were generated by re-referencing to the conventional linked mastoids (L), average (A) and the new 'infinity' (I) reference provided by the reference electrode standardization technique (REST, Yao 2001 Physiol. Meas. 22 693-711). The EEG power in the alpha frequency band with the four different references was calculated and compared with respect to the total energy and spatial amplitude weight centre (AWC) coordinates, to compare the effects of different references on power mapping in the frequency domain. Compared with the I reference, the AWCs of the EEG with the M reference show significant shifts to the right, frontal and superficial positions, the L reference significant shifts to frontal and superficial positions, and the A reference shifts the AWC significantly to a deeper position. Furthermore, the power maps of the M and L references have larger total power than the I reference, while that of the A reference has the smallest total power. These results confirm that different choices of reference electrodes result in systematic changes in the distribution of EEG frequency power, and in order to reduce the effect of such systematic shifts on the explanation of EEG mappings, a common reference is necessary for EEG research. We recommend the I reference for objective use in cross-laboratory studies and clinical practices, as it is far from all the other electrodes and can act as a neutral reference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,427
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909 · cited 3×
“Electrodes were applied to the scalp using a carefully positioned nylon cap in accordance with the 10–5 extension of the International 10–20 electrode system (Oostenveld and Praamstra 2001).”
MethodSelf-citationBarry, R. J., Clarke, A. R., & Johnstone, S. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00362-0 · Cited by 819 · cited 1×
“For example, in the study of AD/HD (attentiondeficit/hyperactivity disorder), the calculation of absolute and relative power estimates were considered as the most commonly used form of EEG analysis (Barry et al 2003).”
MethodGevins, A. (2000) · Cerebral Cortex · doi:10.1093/cercor/10.9.829 · Cited by 599 · cited 1×
“…1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et al 1998), and average (Offner 1950, Nunez et…”
BackgroundA method to standardize a reference of scalp EEG recordings to a point at infinity
Yao, D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/305 · Cited by 576 · cited 12×
“Such an unknown component added to the EEG time course will change the temporal waveform, hence the frequency domain power of the EEG (Lehmann 1988, Maurer 1989, Geselowitz 1998, Yao 2001).”
BackgroundMethodResultSelf-citationNunez, P. L., Wingeier, B. M., & Silberstein, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1030 · Cited by 510 · cited 1×
“…uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et al 1998), and average (Offner 1950, Nunez et al 2001, Rodriguez et al 2004) reference, etc, have been used.”
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448 · cited 1×
“The solution for the surface potential of the three-concentric-sphere model can be found in the literature (Rush and Driscoll 1969, Yao 2000).”
MethodLehmann, D., Strik, W. K., Henggeler, B., Koenig, T., & Koukkou, M. (1998) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00098-6 · Cited by 426 · cited 1×
“The cephalic electrode, such as the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear…”
MethodTheta band power in the human scalp EEG and the encoding of new information
Klimesch, W., Doppelmayr, M., Russegger, H., & Pachinger, T. (1996) · NeuroReport · doi:10.1097/00001756-199605170-00002 · Cited by 422 · cited 1×
“…electrode, such as the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and…”
Background
Cited by
Tenke, C. E., & Kayser, J. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.06.005 · Cited by 273
Graph-based analysis of brain connectivity in schizophrenia
Olejarczyk, E., & Jernajczyk, W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188629 · Cited by 263
Toward an EEG-Based Recognition of Music Liking Using Time-Frequency Analysis
Hadjidimitriou, S. K., & Hadjileontiadis, L. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2217495 · Cited by 260
MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG
Dong, L., Li, F., Liu, Q., Wen, X., Lai, Y., Xu, P., & Yao, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00601 · Cited by 228
“, theoretically desired zero reference), and thus acting as an ideal neutral reference (Yao, 2001; Yao et al., 2005).”
BackgroundMethodInfluentialSelf-citationQin, Y., Xu, P., & Yao, D. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.03.056 · Cited by 209
“This has been shown using a variety of techniques, including EEG spectral imaging (Yao et al., 2005), EEG coherence (Marzetti et al.”
BackgroundMethodInfluentialSelf-citationConnectivity Analysis in EEG Data: A Tutorial Review of the State of the Art and Emerging Trends
Chiarion, G., Sparacino, L., Antonacci, Y., Faes, L., & Mesin, L. (2023) · Bioengineering · doi:10.3390/bioengineering10030372 · Cited by 195
“The scalp power spectra map is demonstrated to be systematically altered in spontaneous EEG with a non-neutral reference signal mixed in other channels, and it is heavily dependent on the chosen reference scheme [344].”
BackgroundHorstmann, M.-T., Bialonski, S., Noennig, N., Mai, H., Prusseit, J., Wellmer, J., Hinrichs, H., & Lehnertz, K. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.013 · Cited by 194
Which Reference Should We Use for EEG and ERP practice?
Yao, D., Qin, Y., Hu, S., Dong, L., Bringas Vega, M. L., & Valdés Sosa, P. A. (2019) · Brain Topography · doi:10.1007/s10548-019-00707-x · Cited by 191
Self-citationArakaki, X., Shoga, M., Li, L., Zouridakis, G., Tran, T., Fonteh, A. N., Dawlaty, J., Goldweber, R., Pogoda, J. M., & Harrington, M. G. (2018) · PLOS ONE · doi:10.1371/journal.pone.0188101 · Cited by 23
Sun, Y., Xu, Y., Lv, J., & Liu, Y. (2022) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2022.108282 · Cited by 11
Metadata
- Authors
- Yao, D., Wang, L., Oostenveld, R., Nielsen, K. D., Arendt-Nielsen, L., & Chen, A. C. N.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2005-02-10
- Volume
- 26
- Issue
- 3
- Pages
- 173-184
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1999127827
- Cited by
- 172
- References
- 40
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.