A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Based on EEG data recorded from 11 subjects with eyes open and the left mastoid (M) reference, three data sets were generated by re-referencing to the conventional linked mastoids (L), average (A) and the new 'infinity' (I) reference provided by the reference electrode standardization technique (REST, Yao 2001 Physiol. Meas. 22 693-711). The EEG power in the alpha frequency band with the four different references was calculated and compared with respect to the total energy and spatial amplitude weight centre (AWC) coordinates, to compare the effects of different references on power mapping in the frequency domain. Compared with the I reference, the AWCs of the EEG with the M reference show significant shifts to the right, frontal and superficial positions, the L reference significant shifts to frontal and superficial positions, and the A reference shifts the AWC significantly to a deeper position. Furthermore, the power maps of the M and L references have larger total power than the I reference, while that of the A reference has the smallest total power. These results confirm that different choices of reference electrodes result in systematic changes in the distribution of EEG frequency power, and in order to reduce the effect of such systematic shifts on the explanation of EEG mappings, a common reference is necessary for EEG research. We recommend the I reference for objective use in cross-laboratory studies and clinical practices, as it is far from all the other electrodes and can act as a neutral reference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,427
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
The five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909 · cited 3×
“Electrodes were applied to the scalp using a carefully positioned nylon cap in accordance with the 10–5 extension of the International 10–20 electrode system (Oostenveld and Praamstra 2001).”
MethodSelf-citationBarry, R. J., Clarke, A. R., & Johnstone, S. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00362-0 · Cited by 819 · cited 1×
“For example, in the study of AD/HD (attentiondeficit/hyperactivity disorder), the calculation of absolute and relative power estimates were considered as the most commonly used form of EEG analysis (Barry et al 2003).”
MethodGevins, A. (2000) · Cerebral Cortex · doi:10.1093/cercor/10.9.829 · Cited by 599 · cited 1×
“…1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et al 1998), and average (Offner 1950, Nunez et…”
BackgroundA method to standardize a reference of scalp EEG recordings to a point at infinity
Yao, D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/305 · Cited by 576 · cited 12×
“Such an unknown component added to the EEG time course will change the temporal waveform, hence the frequency domain power of the EEG (Lehmann 1988, Maurer 1989, Geselowitz 1998, Yao 2001).”
BackgroundMethodResultSelf-citationNunez, P. L., Wingeier, B. M., & Silberstein, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1030 · Cited by 510 · cited 1×
“…uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et al 1998), and average (Offner 1950, Nunez et al 2001, Rodriguez et al 2004) reference, etc, have been used.”
EEG Electrode Sensitivity-An Application of Reciprocity
Rush, S., & Driscoll, D. A. (1969) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1969.4502598 · Cited by 448 · cited 1×
“The solution for the surface potential of the three-concentric-sphere model can be found in the literature (Rush and Driscoll 1969, Yao 2000).”
MethodLehmann, D., Strik, W. K., Henggeler, B., Koenig, T., & Koukkou, M. (1998) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00098-6 · Cited by 426 · cited 1×
“The cephalic electrode, such as the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear…”
MethodTheta band power in the human scalp EEG and the encoding of new information
Klimesch, W., Doppelmayr, M., Russegger, H., & Pachinger, T. (1996) · NeuroReport · doi:10.1097/00001756-199605170-00002 · Cited by 422 · cited 1×
“…electrode, such as the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and…”
BackgroundNunez, P. L., Silberstein, R. B., Cadusch, P. J., Wijesinghe, R. S., Westdorp, A. F., & Srinivasan, R. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90112-0 · Cited by 421 · cited 6×
“After the discussions shown above about the I reference and the other three popular references, the relations between the I reference and other available reference-free techniques should be considered, for example the scalp Laplacian (SL) (Hjorth 1975) emphasizes shallow and localized sources because the differential…”
BackgroundMethodResultInfluentialIssues in the application of the average reference: Review, critiques, and recommendations
Dien, J. (1998) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03209414 · Cited by 419 · cited 6×
“…this problem, great effort has been put in to finding a relative non-active point on the body surface, and arguments on this topic have existed for a long time (Geselowitz 1998, Dien 1998, Desmedt et al 1990, Wolpaw and Wood 1982, Maurer 1989, Pascual-Marqui and Lehmann 1993, Hagemann et al 2001).”
BackgroundInfluentialEEG power, frequency, asymmetry and coherence in male depression
Knott, V., Mahoney, C., Kennedy, S., & Evans, K. (2001) · Psychiatry Research: Neuroimaging · doi:10.1016/s0925-4927(00)00080-9 · Cited by 407
Bruder, G. E., Fong, R., Tenke, C. E., Leite, P., Towey, J. P., Stewart, J. E., McGrath, P. J., & Quitkin, F. M. (1997) · Biological Psychiatry · doi:10.1016/s0006-3223(96)00260-0 · Cited by 353 · cited 1×
“The cephalic electrode, such as the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear…”
MethodHauk, O. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.018 · Cited by 300 · cited 1×
“…Vm, we have Vm = GmS. (8) Based on the Moore–Penrose generalized inverse, a minimum norm solution (MNS), which is a valuable method whenever no reliable a priori information about source generators is available (Hauk 2004), we have S = G+mVm. (9) The symbol (∗)+ denotes the generalized inverse.”
MethodElectroencephalography: Basic Principles, Clinical Applications and Related Fields
Barlow, J. S. (1983) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1983.03340220076048 · Cited by 281
The quest for the EEG reference revisited: A glance from brain asymmetry research
HAGEMANN, D., NAUMANN, E., & THAYER, J. F. (2001) · Psychophysiology · doi:10.1017/s0048577201001081 · Cited by 244
Mima, T., & Hallett, M. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00238-2 · Cited by 212 · cited 1×
“The choice of EEG reference electrode is a critical issue for many studies (Hagemann et al 2001, Mima and Hallett 1999).”
BackgroundAcute mobile phone operation affects neural function in humans
Croft, R. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00215-8 · Cited by 198 · cited 1×
“…et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et al 1998), and average (Offner 1950, Nunez et al 2001, Rodriguez et…”
BackgroundMichel, C. M., Lehmann, D., Henggeler, B., & Brandeis, D. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90180-p · Cited by 186 · cited 1×
“The amplitude amplifying effect of the both mastoid references (figure 2) can be reasonably explained if we assume the generators of the alpha are mainly located in the parieto-occipital area (Michel et al 1992).”
BackgroundTopographic Brain Mapping of EEG and Evoked Potentials
(1989) · Springer eBooks · doi:10.1007/978-3-642-72658-3 · Cited by 169 · cited 3×
“…this problem, great effort has been put in to finding a relative non-active point on the body surface, and arguments on this topic have existed for a long time (Geselowitz 1998, Dien 1998, Desmedt et al 1990, Wolpaw and Wood 1982, Maurer 1989, Pascual-Marqui and Lehmann 1993, Hagemann et al 2001).”
BackgroundThe EEG as potential mapping: The value of the average monopolar reference
Offner, F. F. (1950) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(50)90040-x · Cited by 147 · cited 2×
“The commonly recommended average (A) reference (Offner 1950) assumes that the mean of all recording channels is approximately neutral.”
BackgroundEEG cohererence and reference signals: experimental results and mathematical explanations
Essl, M., & Rappelsberger, P. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523206 · Cited by 121 · cited 1×
“…the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al…”
BackgroundHigh resolution quantitative EEG analysis
Szava, S., Valdes-Sosa, P. A., Biscay, R., Galán, L., Bosch, J., Clark, I., & Jiménez, J. C. (1994) · Brain Topography · doi:10.1007/bf01187711 · Cited by 97 · cited 1×
“In order to make sure that the difference is not due to chance, a one-way repeated-measures ANOVA was conducted on the log10 transformed total power values (Szava et al 1994) of the 11 subjects.”
MethodGeselowitz, D. B. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.646230 · Cited by 96 · cited 8×
“Such an unknown component added to the EEG time course will change the temporal waveform, hence the frequency domain power of the EEG (Lehmann 1988, Maurer 1989, Geselowitz 1998, Yao 2001).”
BackgroundInfluentialDesmedt, J. E., Chalklin, V., & Tomberg, C. (1990) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(90)90063-j · Cited by 95 · cited 3×
“…this problem, great effort has been put in to finding a relative non-active point on the body surface, and arguments on this topic have existed for a long time (Geselowitz 1998, Dien 1998, Desmedt et al 1990, Wolpaw and Wood 1982, Maurer 1989, Pascual-Marqui and Lehmann 1993, Hagemann et al 2001).”
BackgroundSpontaneous EEG theta activity controls frontal visual evoked potential amplitudes
Başar, E., Rahn, E., Demıralp, T., & Schürmann, M. (1998) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(97)00039-7 · Cited by 93 · cited 1×
“…1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson…”
BackgroundScalp distribution of human auditory evoked potentials. I. Evaluation of reference electrode sites
Wolpaw, J. R., & Wood, C. C. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90227-9 · Cited by 88 · cited 2×
“…this problem, great effort has been put in to finding a relative non-active point on the body surface, and arguments on this topic have existed for a long time (Geselowitz 1998, Dien 1998, Desmedt et al 1990, Wolpaw and Wood 1982, Maurer 1989, Pascual-Marqui and Lehmann 1993, Hagemann et al 2001).”
BackgroundImproved realistic Laplacian estimate of highly-sampled EEG potentials by regularization techniques
Babiloni, F., Carducci, F., Babiloni, C., & Urbano, A. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00124-7 · Cited by 78 · cited 1×
“…resolution by extrapolating the scalp potential inward to the cortical surface, and in this extrapolation process there is an amplification of the high spatial frequency components, which is a similar phenomena to that in the scalp Laplacian (Nunez et al 1994, Babiloni et al 1998, Yao 2000, 2001).”
ResultTopographical reliability of mesio-temporal sources of interictal spikes in temporal lobe epilepsy
Merlet, I., Garcı́a-Larrea, L., Ryvlin, P., Isnard, J., Sindou, M., & Mauguı̀ere, F. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00055-8 · Cited by 72 · cited 1×
“…uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et al 1998), and average (Offner 1950, Nunez et al 2001, Rodriguez et al 2004) reference, etc, have been used.”
Lehmann, D., Strik, W. K., Henggeler, B., & Koenig, T. W. (1998) · Cited by 71
Pascual-Marqui, R. D., & Lehamann, D. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90043-o · Cited by 66 · cited 4×
“From equations (7) and (8) we see that the source (S) is the same, which reflects the fact that the reference does not affect the localization of neural active sources in the case of noise free scalp potentials (Geselowitz 1998, Pascual-Marqui and Lehmann 1993).”
BackgroundInfluentialDependence of coherence measurements on EEG derivation type
Andrew, C. M., & Pfurtscheller, G. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520079 · Cited by 63 · cited 1×
“The cephalic electrode, such as the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear…”
MethodEstimation of the EEG power spectrum using MRI T2 relaxation time in traumatic brain injury
Thatcher, R. W., Biver, C. J., Gómez, J. F., North, D. M., Curtin, R., Walker, R. A., & Salazar, A. Μ. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00609-5 · Cited by 61 · cited 1×
“…2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et…”
BackgroundRodriguez, G., Vitali, P., Canfora, M., Calvini, P., Girtler, N. G., Leo, C. D., Piccardo, A., & Nobili, F. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00321-3 · Cited by 58 · cited 1×
“…uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear (Gevins and Smith 2000, Croft et al 2002, Newton et al 2003), neck ring (Katznelson 1981), Oz (Merlet et al 1998), and average (Offner 1950, Nunez et al 2001, Rodriguez et al 2004) reference, etc, have been used.”
High-resolution EEG mappings: a spherical harmonic spectra theory and simulation results
Dezhong, Y. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00205-9 · Cited by 52
The use of a non-cephalic reference electrode in recording cerebral evoked potentials in man
Lehtonen, J. B., & Koivikko, M. J. (1971) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(71)90185-4 · Cited by 45 · cited 2×
“The analysis of data thus recorded assumes that the mastoid is relatively inactive, however this has been persuasively shown to be false (Lehtonen and Koivikko 1971, Hagemann et al 2001).”
BackgroundA method for combining MEG and EEG to determine the sources
Cohen, D., & Cuffin, B. N. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/013 · Cited by 42 · cited 1×
“As noted, the MEG does not detect a radial source, but only a tangential source, while the EEG sees both the radial source and tangential source, and so a combination of EEG and MEG is encouraged in solving the inverse problem (Cohen and Cuffin 1987).”
Chen, A. C. N., Niddam, D. M., Crawford, H. J., Oostenveld, R., & Arendt‐Nielsen, L. (2002) · Neuroscience Letters · doi:10.1016/s0304-3940(02)00512-8 · Cited by 41 · cited 1×
“Both the evoked potential (EP) and the spontaneous potential (EEG) of neural activities are currently read in terms of components thought to reflect distinct neural generators (Desmedt et al 1990, Chen et al 2002, Niedermeyer and Lopes da Silva 1999).”
BackgroundSelf-citationAbsence of gaze direction effects on EEG measures of sensorimotor function
Hesse, C. W., Seiss, E., Bracewell, R. M., & Praamstra, P. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00302-x · Cited by 15 · cited 1×
“The cephalic electrode, such as the vertex (Cz) (Bruder et al 1997, Lehmann et al 1998, Hesse et al 2004), the tip of the nose (Andrew and Pfurtscheller 1996, Klimesch et al 1996, Essl and Rappelsberger 1998), uni-mastoid or ear (Basar et al 1998, Thatcher et al 2001), linked mastoids or ear…”
Method
Cited by
Tenke, C. E., & Kayser, J. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.06.005 · Cited by 273
Graph-based analysis of brain connectivity in schizophrenia
Olejarczyk, E., & Jernajczyk, W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188629 · Cited by 263
Toward an EEG-Based Recognition of Music Liking Using Time-Frequency Analysis
Hadjidimitriou, S. K., & Hadjileontiadis, L. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2217495 · Cited by 260
MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG
Dong, L., Li, F., Liu, Q., Wen, X., Lai, Y., Xu, P., & Yao, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00601 · Cited by 228
“, theoretically desired zero reference), and thus acting as an ideal neutral reference (Yao, 2001; Yao et al., 2005).”
BackgroundMethodInfluentialSelf-citationQin, Y., Xu, P., & Yao, D. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.03.056 · Cited by 209
“This has been shown using a variety of techniques, including EEG spectral imaging (Yao et al., 2005), EEG coherence (Marzetti et al.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Yao, D., Wang, L., Oostenveld, R., Nielsen, K. D., Arendt-Nielsen, L., & Chen, A. C. N.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2005-02-10
- Volume
- 26
- Issue
- 3
- Pages
- 173-184
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1999127827
- Cited by
- 172
- References
- 40
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.