CoChat

Nonlinear characteristics of blood oxygen saturation from nocturnal oximetry for obstructive sleep apnoea detection

Álvarez, D, Hornero, R, Abásolo, D, Campo, F del, Zamarrón, C · 2006 · Physiological Measurement
Cited by 105

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Nocturnal oximetry is an attractive option for the diagnosis of obstructive sleep apnoea (OSA) syndrome because of its simplicity and low cost compared to polysomnography (PSG). The present study assesses nonlinear analysis of blood oxygen saturation (SaO(2)) from nocturnal oximetry as a diagnostic test to discriminate between OSA positive and OSA negative patients. A sample of 187 referred outpatients, clinically suspected of having OSA, was studied using nocturnal oximetry performed simultaneously with complete PSG. A positive OSA diagnosis was found for 111 cases, while the remaining 76 cases were classified as OSA negative. The following oximetric indices were obtained: cumulative time spent below a saturation of 90% (CT90), oxygen desaturation indices of 4% (ODI4), 3% (ODI3) and 2% (ODI2) and the delta index (Delta index). SaO(2) records were subsequently processed applying two nonlinear methods: central tendency measure (CTM) and Lempel-Ziv (LZ) complexity. Significant differences (p < 0.01) were found between OSA positive and OSA negative patients. Using CTM we obtained a sensitivity of 90.1% and a specificity of 82.9%, while with LZ the sensitivity was 86.5% and the specificity was 77.6%. CTM and LZ accuracies were higher than those provided by ODI4, ODI3, ODI2 and CT90. The results suggest that nonlinear analysis of SaO(2) signals from nocturnal oximetry could yield useful information in OSA diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/27/4/006

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 105

Metadata

Authors
Álvarez, D., Hornero, R., Abásolo, D., Campo, F. D., & Zamarrón, C.
Venue
Physiological Measurement
Published
2006-03-14
Volume
27
Issue
4
Pages
399-412
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2013405048
Cited by
105
References
3
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nonlinear characteristics of blood oxygen saturation from nocturnal oximetry for obstructive sleep apnoea detection. https://app.cochat.ai/papers/10.1088/0967-3334/27/4/006
The paper
Álvarez, D., Hornero, R., Abásolo, D., Campo, F. D., & Zamarrón, C. (2006). Nonlinear characteristics of blood oxygen saturation from nocturnal oximetry for obstructive sleep apnoea detection. Physiological Measurement. https://doi.org/10.1088/0967-3334/27/4/006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.