Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach

Open access
Li, Yandong, Ma, Zhongwei, Lu, Wenkai, Li, Yanda·2006·Physiological Measurement

Abstract

Independent component analysis (ICA) proves to be effective in the removing the ocular artifact from electroencephalogram recordings (EEG). While using ICA in ocular artifact correction, a crucial step is to correctly identify the artifact components among the decomposed independent components. In most previous works, this step of selecting the artifact components was manually implemented, which is time consuming and inconvenient when dealing with a large amount of EEG data. We present a new method which automatically selects the eye blink artifact components based on the pattern of their scalp topographies, which can be exemplified as a template matching approach. The feasibility of using a fixed template for singling out the eye blink component after ICA decomposition was validated by an experiment in which 18 subjects among the 21 subjects involved exhibited a highly consistent pattern of eye blink scalp topographies. Since only the spatial feature is employed for singling out the eye blink component, the proposed method is very efficient and easy to implement. Objective evaluation of the real results shows that the proposed algorithm can remove the eye blink artifact from the EEG while causing little distortion to the underlying brain activities.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/27/4/008

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 197

Metadata

Authors
Li, Y., Ma, Z., Lu, W., & Li, Y.
Venue
Physiological Measurement
Published
2006-03-14
Volume
27
Issue
4
Pages
425-436
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2009782817
Cited by
197
References
2
FWCI
2.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach. https://app.cochat.ai/papers/10.1088/0967-3334/27/4/008
The paper
Li, Y., Ma, Z., Lu, W., & Li, Y. (2006). Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach. Physiological Measurement. https://doi.org/10.1088/0967-3334/27/4/008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.